Operating

and

Installation Instructions

CHARNWOOD

COUNTRY 6 FT

Summary of Contents for COUNTRY 6 FT

Page 1: ...Operating and Installation Instructions CHARNWOOD COUNTRY 6 FT ...

Page 2: ...may find it helpful to try several fuels to find the most suitable If you are unable to obtain the fuel you want ask your supplier or an approved fuel distributor to suggest an alternative Only smokeless fuels may be burnt in smoke control areas PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE DOOR OPERATION Using the tool turn the right hand door knob...

Page 3: ...ay Never allow the ash to accumulate in the ashpan so that it comes in contact with the underside of the grate as this will seriously damage the grate Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins After emptying the ashpan poke the fire with a poker to clear the firebed of ash To make ash removal easier when burning coal or smokeless fuel there is a...

Page 4: ...s removed from all horizontal surfaces after sweeping In situations where it is not possible to sweep through the appliance the installer will have provided alternative means such as a soot door After sweeping the chimney the appliance flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush After clearing any soot from within the stove replace the throat...

Page 5: ...ry seek professional advice The most common cause of fume emission is flueway or chimney blockage For your own safety these must be kept clean Fire blazing out of control Check that a The doors are tightly closed b The airslides are turned down to the minimum setting c The airwash control is closed d A suitable fuel is being used e Door seals and airwash slide are intact Chimney Fires If the chimn...

Page 6: ...supply into the room in which the appliance is installed totalling at least 100 square cm 16 square inches to provide combustion air This is particularly necessary if the room is double glazed In addition to these instructions the requirements of BS 8303 and BS 6461 Pt 1 2 1984 must be fulfilled Local Authority Bylaws and Building Regulations regarding the installation of Solid Fuel burning applia...

Page 7: ...ut the knock outs for the boiler tappings in the back of the firebox Fit one back nut on the flow tapping to come flush with the back face of the boiler and fit the boiler into the appliance Place the fibre washers over the tappings on the outside of the appliance and fit the two remaining backnuts ensuring that the boiler is held tightly against the rear inside face of the appliance and that the ...

Page 8: ... swept The optional vertical rear flue connector does allow the chimney to be swept through the stove except when a boiler is fitted Soot doors may either be in the actual brickwork of the chimney or in the register plate Various positions of soot doors are shown in Figs 4 to 7 PRE LIGHTING CHECK If the optional boiler is fitted then the throat plate is not required If the optional boiler is not f...