re-tighten the locking nut. Ensure that
the flap opens and closes freely as the
knob is turned.

Before initial lighting the following
points should be checked :-

1. The bottom grate bars must all be
fitted and should move freely and
easily when the riddling mechanism is
operated.

2. The plates round the sides and back
of the grate must be in position and
sitting correctly.

PRE LIGHTING

CHECK

3. The throat plate must be fitted in the
roof of the appliance and should be
checked to ensure that it has not
become dislodged in transit. The
method of location and positioning of
the throat plate is shown in Fig. 3.

On completion of the installation and
after allowing a suitable period of time
for the fire cement and mortar to dry
out, the stove should be lit and
checked to ensure that smoke and
fumes are taken from the appliance up
the chimney and emitted safely. Also
check all joints and seals.

COMMISSIONING

The central heating pump should be
adjusted to give the correct water flow
against the circuit resistance and the
system should be correctly balanced.

On completion of the installation and
commissioning please leave the
operating instructions with the
customer and advise on the use of the
appliance and any controls on the
system.

Country 14B Dimensions

(All dimensions are in mm)

Page 8

Country 14B 09/03

Flue connection may

be Top or Rear

357

340

616

570

601

ø154

731

389

136

683

451

344

136

789

136

608

Boiler tappings are 1" BSP Female

Summary of Contents for Country 14B

Page 1: ...stallation Instructions C H A R N W O O D B i s h o p s W a y N e w p o r t I s l e o f W i g h t P O 3 0 5 W S U n i t e d K i n g d o m T 4 4 0 1 9 8 3 5 3 7 7 9 9 F 4 4 0 1 9 8 3 5 3 7 7 8 8 c h a r n w o o d a j w e l l s c o u k w w w c h a r n w o o d c o m ...

Page 2: ...At first you may find it helpful to try several fuels to find the most suitable If you are unable to obtain the fuel you want ask your supplier or an approved fuel distributor to suggest an alternative Use the door opening and ashpan tool to open and close the doors Turn the right hand door knob anti clockwise to open and clockwise to close see Fig 1 Your Charnwood stove is fitted with a multifuel...

Page 3: ...p The ashpans should be emptied regularly before it becomes too full Never allow the ash to accumulate in the ashpans so that it comes in contact with the underside of the grate as this will seriously damage the grate bars The ashpans are handled using the tool provided Care should be taken to ensure that ash is cool before emptying it into plastic liners or bins To make ash removal easier there i...

Page 4: ...y the appliance flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush After clearing any soot from within the stove replace the throat plate see Fig 3 the front firebars and side fireplates Different types of sweep s brushes are available to suit different flueways For standard brick chimneys a wire centre sweep s brush fitted with a guide wheel is rec...

Page 5: ...ed d the fire is not fitted onto a heating system which is too large Do not light the fire if there is any possibility that any parts of the system may be frozen Check that a the fire is burning properly if not then carry out the checks under Fire Will Not Burn Over Firing Freezing Lack of Heat To Radiators Hot Water b the throat plate is fitted correctly see Fig 3 and that it is not distorted c t...

Page 6: ...himney is in poor condition then expert advice should be sought regarding the necessity of having the chimney lined If it is found necessary to line the chimney then a lining suitable for Solid Fuel must be used If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BS 4543 can be used either internally or externally These chimneys mus...

Page 7: ...e expected Fitting a radiator in the same room as the fire is recommended as it will allow greater flexibility in the way that the system is operated as well as ensuring that there is sufficient heat Connect the heating system to the boiler ensuring that the primary flow pipe rises continuously from the appliance to the vent Fill the system with water and check for leaks The circulating pump may b...

Page 8: ...ugh the appliance but in most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept This may either be in the actual brickwork of the CONNECTIONS TO FLUES SOOT DOORS chimney or in the register plate Various types and positions of soot doors are shown in figures 8 to 10 Before lighting the fire check the cold setting distance of the thermostat Remove t...

Page 9: ...of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the stove should be lit and checked to ensure that smoke and fumes are taken from the appliance up the chimney and emitted safely Also check all joints and seals COMMISSIONING The central heating pump should be adjusted to give the correct water flow against the circuit resistance and the sys...

Page 10: ... 49 010 BW51 Ash Carrier Optional Extra 14 004 FV15 Secondary Air Rod 50 008 TH02 L Low Level Pipe Stat Opt l Extra 15 002 EW15 Side Fire Plate 51 002 DY18 R H Door Knob Spindle 16 002 BV16 Back Fire Plate 52 002 KV14 Door Catch Cam 17 002 CG01 Bottom Grate Bar 18 002 CG01S14 Set of Grate Bars 14 per set 19 004 FV17L Left Hand Ashpan 20 004 FV17R Right Hand Ashpan 21 004 BV19 Ash Shedding Plate 22...

Page 11: ... a y N e w p o r t I s l e o f W i g h t P O 3 0 5 W S U n i t e d K i n g d o m T 4 4 0 1 9 8 3 5 3 7 7 9 9 F 4 4 0 1 9 8 3 5 3 7 7 8 8 c h a r n w o o d a j w e l l s c o u k w w w c h a r n w o o d c o m Your Local Charnwood Dealer ...

Reviews: