23
PIC8-3
b) Put the black board on the up-looking round camera---------
adjust the board’s
position-------- make the two center points matching --------press set go to next
step-------machine change to down-looking camera automatically------next display
will show as below:
PIC8-4
c) Press arrow to move the head --------make the down-looking camera match the
black board cross check ------- press set ------- calibrate done.
(2)
Nozzle2 position calibrate:
after set well the nozzle1 position, then set the
nozzle2. Aim at the center of the cross.
(3)
Vacuum detection set:
(please refer below page 24 for detail)
(4)
Use system stack offset:
if turn on this function, stack offset will be saved in
system, different work files all use one same offset. If turn off this function, stack
offset will be saved in work file (not system), different work files have different
offset information.
(Usually we suggest turn off this function)
(5)
Model parameter set:
press it goes to image as below, it is the setting for Mark2
point auto positioning function. “Model size” is the size of the model, usually you
can set as 50-
100. “Match area size” is the range of searching target, bigger size,
longer searching t
ime. When match area size is smaller than “Match threshold”,
machine will not detect the mark point, so auto calibrate mark point failure.