Charmhigh-V1.0-2016 |
33
All Rights Reserved
calibrated before do this calibration;
(3)
Single pull needle offset calibration:
Click button and input material stack ID,
adjust position of pull needle in popup window, see figure below, adjusting the
tape let the red circle touches the blue line, the place of green circle is just the
suggested pull needle position;
Figure.
11-5
(4)
Entire pull needle offset calibration:
Adjusting process is similar to above, but
the result will affect position of pull needle for all of material stack, therefore it‟s
appropriate for the situation that pull needle with entire deviation;
(5)
Use sys. stack offset:
Click to open or close use system material stack offset, if
use system offset then all of offset information in work file will kept in system,
otherwise offset information in work file kept in itself.
(6)
Vacuum detection set:
Used for viewing and setting parameters of vacuum
pump;
(7)
TS Calibrate:
Used for touch screen calibrate,system will restart after calibration.
(8)
Backup/
Restore:
Backup and restore all of parameters in system set;
(9)
Save:
Click to save updates of system set, note, if system parameters were
modified without saving, then parameters that before modification will be restored
when machine restart.