![Charlton & Jenrick Valor LEX2 Instruction Manual Download Page 21](http://html.mh-extra.com/html/charlton-and-jenrick/valor-lex2/valor-lex2_instruction-manual_2591714021.webp)
18
Window Open Detection
6b.34
When the transmitter detects a rapid drop in
room temperature, it will be judged as a window
open, the warning icon will be displayed, and the
heater will be turned off automatically.
6b.35
After the indoor temperature has risen or a manual
override of the warning (by operating remote control)
has been done, the fire will return to normal working
state.
Set up the communication between the remote and
appliance
6b.36
The operations below should be carried out before
programming in the case of replacing the remote
control or the appliance cannot be controlled by the
remote:
⚫
Hold the reset button on the appliance for 3 seconds
(pen Point may needed) until you hear 3 short beeps
from the unit, release the button.
⚫
Press the
button on the rem ot e, the
programm ing is f inis hed when you hear a long
beep from the applianc e.
6b.37
Res etting the code for remote control is
necessary if the appliance operates wrongly or the
remote control does not operate correctly.
⚫
Open the back cover of the remote control.
⚫
Press the Reset button on remote control
.
⚫
Refit the back cover of the remote control
⚫
Follow the steps 6b.36
Important Safety Information for Remote Controls
6b.38
To remove the batteries, open the back cover of the
remote control to remove the batteries and replace with
new one. Pay attention to the positive and negative
poles.
RESET
6b.39
Two AAA R03 alkaline batteries are required for the
remote control.
6b.40
Exhausted batteries are to be removed from
the appliance and safely disposed of.
6b.41
These Non-rechargeable batteries are not to be
recharged.