10
GO ECO Range
Issue 01.1 05/17
6.0
Technical Data & Declaration of Performance (DoP)
Manufacturer: Charlton & Jenrick Ltd.
Range Designation: GO ECO freestanding stoves.
Models: GO ECO 5, 5 Wide, 5 Plus and 5 Wide Plus with nominal outputs of 5kW.
Intended Use: Domestic heating appliances
Independently Performance & Safety tested by: Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System: ISO9001
Signed:
Peter Mintoft
Director
April 2017
NOTE: Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are
comparative only. They do not relate directly to re-fuelling intervals that can be achieved on an installed product. Re-fuelling
intervals of 1-1.5h for wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal conditions on a
low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Model
Go Eco and Go Eco
Plus 5
Go Eco and Go
Eco Plus 5 Wide
Notes
Appliance weight (packed/unpacked) (Kg):
60/50 63/53
70/59 74/63
Approximate Output Range: (kW)
3.8 – 6.7
4.1-7.0
Harmonised EN European Standard (hEN):
EN13240: 2001
Amd 2: 2004
EN13240: 2001
Amd 2: 2004
Additional Characteristics Test Standard:
DIN +
DIN +
Additional Particulate Emission Test Standard:
PD6434
PD6434
Performance Characteristics using Wood Fuel
Test Report Issue Date:
04/17
04/17
Total Efficiency: (%)
82.5
79.8
Declared nominal output: (kW)
5
5
Tested nominal Output: (kW)
5.1
5
Tested wood re-fuelling interval: (h)
0.81
0.79
Flue gas mass flow: (g/s)
3.6
4.2
Mean CO emission (@13% O
2
) : (%) (Nmg/m
3
)
0.06 (750)
0.09 (1125)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
37
46
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
101
92
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
10
11
PD6434 Particulate Emissions High output: (gh
-1
)
3.6
1.9
PD6434 Particulate Emissions Low output: (gh
-1
)
1.9
1.5
Optical Density Time > 0.2 High (Mins)
1.1
0.4
Optical Density Time > 0.2 Low (Mins)
0.7
0.0
*Mean Flue Temperature: (Deg C)
270
276
Approximate Max Log Length: (mm)
250
350
Performance Characteristics using Maxibrite Fuel
Total Efficiency: (%):
77
78.7
Declared nominal output: (kW)
5.0
5.0
Tested nominal output: (kW)
5.0
5.0
Tested re-fuelling interval: (h)
1.03
1.03
Flue gas mass flow: (g/s)
4.0
3.2
Mean CO emission (@13% O
2
) : (%) (Nmg/m
3
)
0.06 (720)
0.02 (250)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
8
2
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
131
91
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
15
13
Mean Flue Temperature: (Deg C)
314
327
Clearances from Combustible Materials
Side Wall: (mm)
700
700
Rear Wall: (mm)
450/300
550/300