If you have two battery and total cell count is over 6S such as 5S+5S, 4S+4S, 6S+6S, 5S+3S, 3S+6S, and so on
The connection is as below, two 5S packs will be charged as one 10S pack. For 6S+6S, if battery connector is XH
type, you can connect the battery to balance port directly and need not adapter wire and adapter board.
1.
Connect two or three packs with heavy wire (as same as the Blue wire in following picture). Take two 5S
battery as sample.
2.
Plug 1# battery and 2# battery into two adapter board separately, .
3.
Connect total battery pack positive to charger output port B+, and connect battery negative to output port
B-, finally connect adapter wire to charger balance port.
Important thing is 1# battery must be connected to 1-6S balance port. Otherwise the charger will be damaged.
B-
B+
to adapter board 2#
to adapter board 1#
To charger Output
1#
5S battery
2#
5S battery
Connect to 1-6S
balance port
connect to
1#
battery
5S
Connect to 7-12S
balance port
connect to
2#
battery
5S