![Char-Broil Traditional 4638200 Assembly Manual Download Page 9](http://html.mh-extra.com/html/char-broil/traditional-4638200/traditional-4638200_assembly-manual_2590999009.webp)
4638200 9
Connecting Grill to Natural Gas Source
1. Gas at line leading to grill must be shut off before connecting to
grill.
2. Attach gas supply tube to gas line. Wrench tighten.
Connection to gas source must be done by a certified
plumber.
s
The appliance and its individual shut off valve must
be
disconnected from the gas supply piping
system during
any pressure testing of that
system at test pressures in
excess of 1/2 psig
(3.5kPa).
s
The appliance must be isolated from the gas supply
piping sustem by closing its individual manual
shutoff
valve during any pressure testing of
the gas supply
piping system at test
pressures equal to or less than
1/2 psi (3.5 kPa).
13
After connecting grill to
gas line, perform leak test
Connection from gas source
Gas Supply Tube
at back of grill
Leak Test
For your safety
Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Grill must be leak tested outdoors in well-
ventilated area, away from ignition sources such
as gas fired or electrical appliances. During leak
test, keep grill away from open flames or sparks.
Never remove opening at end of valve (A).
To leak test your grill:
Use a clean paint brush and 50/50 soap and
water solution.
Use mild soap and water.
s
Do not use household
cleaning agents.
Damage to gas train components can result.
1. Turn control knobs to OFF.
2.
Check to make sure grill is connected to natural gas source and gas
supply is turned on.
3.
Brush soapy solution onto following connections:
2
Gas Supply Tube/Pipe (1) and all connections
Valve (2) behind console
Gas supply tube and connection (3)
4. If "growing"
bubbles appear, there is a leak. Turn gas off at control
knobs and gas source immediately. Retighten connections and
repeat leak test procedures. If leaks cannot be stopped, replace
parts. To order new parts call
1-800-993-2677.
14
3
Do not use grill until leak checked.
If leak is detected at any time,
STOP
and correct before using grill
further.
A