![Char-Broil Professional Series 463233503 Assembly, Use And Care Manual Download Page 11](http://html1.mh-extra.com/html/char-broil/professional-series-463233503/professional-series-463233503_assembly-use-and-care-manual_2590941011.webp)
463233503 • 11
• A disconnected LP tank in storage or being transported must
have a safety cap installed (as shown). Do not store an LP
tank in enclosed spaces such as a carport, garage, porch,
covered patio or other building. Never leave a LP tank inside a
vehicle which may become overheated by the sun.
• Do not store LP tank in an area where children play.
Leak Testing Valves, Hoses and Regulator
1. Turn all grill control knobs to OFF.
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning hand wheel counter
clockwise. If you hear a rushing sound, turn gas off
immediately. There is a major leak at the connection. Correct
before proceeding.
LP Tank Removal, Transport And Storage
• Turn OFF all control knobs and LP tank valve. Turn coupling
nut counter clockwise by hand only - do not use tools to
disconnect. Lift LP tank wire upward off of LP tank collar, lift
LP tank up and off of support bracket. Install safety cap onto
LP tank valve. Always use cap and strap supplied with valve.
Failure to use safety cap as directed may result in
serious personal injury and/or property damage.
LP Tank
Valve
Safety
Cap
Retainer
Strap
4. Brush soapy
solution onto
following
connections:
5. "If growing" bubbles
appear, there is a leak. Close
LP tank valve immediately and
retighten connections. If leaks
cannot be stopped "do not try
to repair." Call for replacement
parts. Order new parts by giving the serial, model number
and name of items needed to the Grill Service Center
at
!
1-800-241-7548.
6. Always close LP tank valve after performing leak test by
turning hand wheel clockwise.
Safety Tips
▲
▲
▲
▲
▲
Before opening LP tank valve, check the coupling nut for
tightness.
▲
▲
▲
▲
▲
When grill is not in use, turn off all control knobs and LP tank
valve.
▲
▲
▲
▲
▲
Never move grill while in operation or still hot.
▲
▲
▲
▲
▲
When moving the grill push it forward, do not pull from
behind.
▲
▲
▲
▲
▲
Use long-handled barbecue utensils to avoid burns and
splatters.
▲
▲
▲
▲
▲
Do not remove grease receptacle or tray until grill has
completely cooled.
▲
▲
▲
▲
▲
If you notice grease or other hot material dripping from grill
onto valve, hose or regulator turn off gas supply at once.
Determine the cause, correct, clean and inspect valve, hose
and regulator before continuing. Perform a leak test.
▲
▲
▲
▲
▲
The regulator may make a humming or whistling noise
during operation. This will not affect safety or use of grill.
▲
▲
▲
▲
▲
If you have a grill problem see the "Troubleshooting Section".
• NEVER store a spare LP tank under or near grill or in
enclosed areas.
• Never fill the cylinder beyond 80% full. An overfilled
spare LP tank is hazardous due to possible gas
released from the safety relief valve. The safety relief
valve on a LP tank could activate releasing gas and
cause a fire, resulting in serious injury, property
damage or death.
• If you see, smell or hear escaping gas, immediately
get away from the LP tank/grill and call your fire
department.
• All spare LP tanks must have safety caps installed on
the LP tank outlet.
D
D
D
D
DANGER
ANGER
ANGER
ANGER
ANGER