Remove LP Orifices
-
- Insert the Orifice Driving Tool provided with Kit into the Firebox Burner opening, engage the tool with the orifice, and loosen each orifice 1-2
turns, counter-clockwise, from its orifice holder.
DO NOT completely remove the orifices at this point.
5
6
Remove LP Orifices
- Using your fingers in the area illustrated below, unscrew each orifice by hand.
- Save the removed orifices for converting back to LP gas.
Main Burner Conversion (Cont.)
Firebox
Top view of 3 burner firebox with
burner assemblies removed.
Orifice Driving Tool
Firebox Burner
Opening
Orifice
Orifice
Using your fingers,
turn the orifice
counter-clockwise
to remove.
Orifice
Holder
Orifice
Holder
Bracke
t
Firebox Burner
Opening
15