NOTE: Reinstall Screws
4
Pull the Burner Control Knob off of Valve Stem.
Remove Screws and Washers that secure
the
Bezel to the Control Panel. Save removed Bezel for converting back to LP
Tank Gas.
Install new Natural Gas Bezel provided with Kit (see illustration below) in place of old Bezel, on Control Panel and secure
using previously removed Screws and Washers. Assure proper alignment with Control Knob before fully tightening.
Note:
The n
ew
b
ezel will
limit
the rotation
of
the Control Knob
in order
to properly control
gas flow to
your grill.
Press Control Knob back onto Valve Stem. Make adjustments to Bezel for free movement of Control Knob.
5
Correct engagement
Under the firebox, attach the orifice holder with the venturi tube with the screws previous removed.
Bezels
Valve Stem
Screws
Main Burner
Control Knobs
Install bezel with “OFF” at top