Hydraulic Fluid
The DT100 uses
mineral ISO46 HLP hydraulic oil
in the hydraulic circuit. Although the machine is supplied fully
filled and ready for use the level should be checked before first use and as part of the daily checks routine. The oil
level is checked by using the dipstick on the oil filler cap, shown below (cover removed for clarity).
Oil Filler / Dipstick
Oil Level Check Procedure
The hydraulic oil level is checked on the DT100 with the body
fully
raised as follows;
1.
Ensure the DT100 is securely attached to a towing vehicle and raise the bed fully.
2.
Use a prop or block to ensure you are safe when checking the oil level.
NEVER WORK UNDER AN UNPROPPED
BODY!
3.
With the bed fully raised (ie. hydraulic cylinder at full extension) the oil should be at the minimum level marker
of the dipstick. Add or remove oil as required to ensure the correct level.
ALWAYS MAKE SURE THE BODY IS SUITABLY PROPPED WHEN WORKING UNDER THE
ALWAYS MAKE SURE THE BODY IS SUITABLY PROPPED WHEN WORKING UNDER THE
MACHINE