background image

CHAPIN INTERNATIONAL, INC.   P.O. BOX 549  700 ELLICOTT ST. BATAVIA, NY 14021-0549   www.chapinmfg.com   800-950-4458

PowerFLO

 7800 Series

12 Volt DC Motor-Driven Diaphragm Pumps

Specifications —

Motor:

Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated

Leads: 16 AWG, 12” long

Duty Cycle: See Heat Rise graph

Temperature Limits: Motor is not equipped with thermal

   protection. For user safety, optimal performance, and    

   maximum motor life, the motor surface temperature should

   not exceed 150°F (66°C) (see Heat Rise graph above right).
Pump:

Type: 3 chamber positive displacement diaphragm pump, self

priming, capable of being run dry, demand or bypass model.

Certifications: NSF Standard 58

Liquid Temperature: 140°F (60°C) Max.

Priming Capabilities: 14 feet (4 m)

Max Pressure: 60 PSI

Inlet/Outlet Ports:      7802: Quick Attach
Materials of Construction:

Housing: Polypropylene   Diaphragm: Santoprene

Valves: Viton  

 

Fasteners: Stainless steel

Weight: 6 lbs (2.7 kg)

Installation and Operation Precautions —

1.  The pump is equipped with a pressure sensing demand switch that 

     controls the maximum operating pressure.

2.  In addition, never subject the pump to pressures above 125 PSI 

     (8.5 bars).

3.  As long as there is inlet water pressure, the pump will not stop 

     forward flow of water even if the motor is turned off. Be sure the  

     system has positive means of shutting off water supply.

4.  Do not operate pump in an explosive environment. Arcing from the 

     motor brushes, switch or excessive heat from an improperly cycled 

     motor may cause an explosion.

5.  Do not locate the pump motor near low temperature plastics or 

     combustible material. The surface temperature of the motor may 

     exceed 250°F (120°C).

6.  Do not pump gasoline or other flammable liquids. Pump head 

     materials are designed for use with water only. Do not use with 

     petroleum products.

7.  Do not assume fluid compatibility. If the fluid is improperly 

     matched to the pumps’ elastomers, a leak may occur.

8.  To prevent electrical shock, disconnect power before initiating any 

     work. In the case of pump failure, the motor housing and/or pump 

     fluid may carry high voltage to components normally considered 

     safe. Therefore, always consider electrical shock hazard when 

     working with and handling electrical equipment. If uncertain, 

     consult an electrician. Electrical wiring should only be done by a 

     qualified electrician per local and state electrical codes.

Pressure Sensing Demand Switch —

   The PowerFLO Series 7800 pump is controlled by a built-in pressure 

sensing demand switch. When a faucet or valve is opened down stream of 

the pump, line pressure drops thus starting the pump automatically. 

Conversely, when the valve shuts, the line pressure increases turning the 

pump off automatically. The pressure switch actuates in response to the 

pump outlet pressure at a predetermined and preset pressure. The pump 

label indicates the predetermined ON and OFF pressures. Typically, the OFF 

pressure is accurately set at the Factory and the ON pressure is within an 

allowable range below that value. In response to the characteristics of the 

system in which the pump is installed, the flexibility and length of the 

tubing, the faucet or valves and the duration that they are open; these 

pressure settings may vary. Therefore, variation in pressure setting is 

expected with use and over time.

Adjusting the Pressure Switch:

   Should the pressure switch OFF setting vary with use and time to an 

unsuitable value, it may be adjusted for optimum performance. Turn the 

setscrew clockwise to increase the OFF pressure setting and counter 

clockwise to decrease. The screw should not be adjusted more than one 

half turn without consulting the Factory. Excessive adjustment of the 

pressure switch could cause low system pressure, rapid cycling ON/OFF 

operation, and reduced pump and motor life. Damage may occur. The 

Warranty does not cover improper adjustment of the pressure switch.

Servicing —

Every Year: Check system against operating standards.
Every 2-3 Years: We recommend replacing the diaphragm and

checking against operating standards.

* Important return safety instructions:

When you return your pump for warranty or repair, you must always do the 

following:

1. Flush chemical residue from the pump (best done in the field).

2. Tag pump with type of chemicals having been sprayed.

3. Include complete description of operation problem, such as how pump 

    was used, symptoms of malfunction, etc. Since pumps can contain 

    residues of toxic chemicals these steps are necessary to protect all the 

    people who handle return shipments, and to help pinpoint the reason for 

    the breakdown.

Model: 7802: 2.0 GPM

6

17

8

11

2

12

7

15

10

— ASSEMBLAGE DE LA POMPE, DU RÉSERVOIR ET DE LA SOUPAPE

Pour commander des pièces de remplacement : 1-800-950-4458

Instructions d’assemblage

1.0 -- Installer la soupape dans le raccord, comme 

 

illustré, avec un produit d’étanchéité des 

 

filetages de haute qualité, afin de prévenir 

 

les fuites. (NE PAS TROP SERRER)

2.0 -- Insérer le fil conducteur dans la fiche se trouvant 

 

à l’arrière de la pompe.

3.0 -- Joindre le fil rouge du fil conducteur à un connecteur 

 

+12 V sur le tracteur de jardin. Le fil noir doit 

 

être mis à la terre ou connecté à la borne 

 

négative de la batterie.

Liste des pièces

DESCRIPTION

PIÈCE N°

QTÉ

ARTICLE

1

1

1

2

Assemblage du boyau d’aspiration

RP00133N

Ensemble collecteur (sans soupape)

RP00132N

1

3

Jauge 0 à 100 psi

RP00004N

1

4

Vis 10-24 x 1-1/4 po

RP00128N

4

5

Réservoir de 95 litres (25 gal)

RP00116N

1

6

Couvercle de réservoir

RP00005N

1

7

Trousse, bouchon de drainage

RP00017N

1

8

Vis sans fin

010987

3

9

Pince, pistolet (paire) et vis

RP00014N

2

10

1

11

Ensemble de fil principal avec 

interrupteur 2,4 m (96 po)

RP00006N

1
1

12
13

Pompe 2,2 gpm

RP00134N

1

15

EL12 QD Fixation

RP00135N

1

16

Oeillet de caoutchouc

RP00114N

1

17

Ensemble de boyau de décompression

RP00125N

Réservoir de 57 litres (15 gal)

RP00115N

1

18

Baguette anti-goutte

RP0008N

Trousse de buse

RP00099N

Boyau (15 pi ou 4,57 m)

RP00001N

1

14

CHAPIN INTERNATIONAL, INC.   P.O. BOX 549  700 ELLICOTT ST. BATAVIA, NY 14021-0549   www.chapinmfg.com   800-950-4458

18

 

 

 

 

   

   

5

13

14

3

9

16

4

11

1

— FONCTIONNEMENT DES SOUPAPES

Vers la baguette 

de pulvérisation

Tuyau de 

décompression 

vers le haut 

du réservoir.

Pompe

Ce levier permet d’activer 

et de désactiver

la rampe de pulvérisation

Vers la rampe de pulvérisation 

(le cas échéant)

Ce levier règle la pression du système 

en réacheminant le liquide vers le 

réservoir. L’ajustement de ce levier 

augmentera ou diminuera la pression 

dans le tuyau de pulvérisation ou dans 

la rampe de pulvérisation 

French Page 2

Reviews: