13
MAINTENANCE
To ensure that the Tx/Rx Mount and 1.8m SMC Offset Antenna is operating efficiently and at an optimum, moderate main-
tenance is required. We recommend conducting as routine Maintenance Inspection every six months or as needed if
unusual circumstances occur, such as severe weather conditions, falling objects and vandalism. The following checklist is
provided for your convenience.
MAINTENANCE INSPECTION CHECKLIST:
1 - FOUNDATION
■
Structural Damage
2 - Tx/Rx MOUNT
■
All bolts (if any loosening has occurred tighten and torque - refer to Torque Chart Page 2)
■
Structural Damage
■
Corrosion of galvanized steel members (if necessary, repair with cold zinc-rich galvanizing paint)
3 - 1.8m SMC OFFSET ANTENNA
■
Bolts - M12 round head square neck, securing antenna to mount (Correct torque 20 Ft-lbs/27N-m)
■
Structural Damage
4 - BOTTOM FEED SUPPORT TUBE, SIDE FEED SUPPORT STRUTS AND ORU BRACKET
■
All bolts (if loosening has occurred tighten and torque - refer to Torque Chart on Page 2).
■
Structural Damage
■
Corrosion of galvanized steel members (if necessary, repair with cold zinc-rich galvanizing paint)
5 - FEED ASSEMBLY
■
All securing hardware
■
Structural Damage
■
Feed Horn Weather Cover - Physical Damage (if damaged, replace to prevent entry of water)
Upon inspection, make necessary repairs and replace any damaged parts.
For replacement parts, contact:
U.S.A. VSAT Customer Service
CHANNEL MASTER
1315 Industrial Park Drive
Smithfield, NC 27577
(919) 989-2205
■
Fax (919) 989-2200