background image

18

 CS150 VALVE PARTS 

DRAIN CONNECTION

No.

Part No.

Description

Qty.

 

1

20017X284-1

1” NPT Drain Line Elbow

1

2

20125X016

Drain Line Flow Control Retainer

1

3

CS-DLFC-2.4

Drain Line Flow Control, 2.4 gpm

1

CS-DLFC-3

Drain Line Flow Control, 3 gpm

CS-DLFC-3.5

Drain Line Flow Control, 3.5 gpm

CS-DLFC-4

Drain Line Flow Control, 4 gpm

CS-DLFC-5

Drain Line Flow Control, 5gpm

CS-DLFC-8

Drain Line Flow Control, 8 gpm

CS-DLFC-9

Drain Line Flow Control, 9 gpm

CS-DLFC-10

Drain Line Flow Control, 10 gpm

CS-DLFC-12

Drain Line Flow Control, 12 gpm

CS-DLFC-15

Drain Line Flow Control, 15 gpm

CS-DLFC-20

Drain Line Flow Control, 20 gpm

CS-DLFC-25

Drain Line Flow Control, 25 gpm

Drawing A

3

2

1

Summary of Contents for 20125X500

Page 1: ...Chandler Systems Commercial Control Valve Manual CS125 CS150 Series ...

Page 2: ... you with many other resources for you to learn more Feel free to call Chandler Systems when you need additional help We also have many resources located on our website including instructional videos and images DROP Connect is also active on various social media pages Feel free to follow us for the most up to date information and news dropconnect FCC Compliance Statement https dropconnect com site...

Page 3: ...neration 8 Advanced Configuration 9 Quick Reference Table 11 Injectors 12 Connections 13 CS125 Valve Breakdown 14 CS125 Brine Connection 15 CS125 Injector Assy 16 CS150 Valve Breakdown 17 CS150 Drain Connection 18 CS150 Brine Connection 19 CS150 Injection Assy 20 CS125 CS150 Powerhead 21 Valve Body Flow Diagrams 22 DROP Warranty 28 ...

Page 4: ...4 DROP VALVES DROP CS150 Commercial Softener Valve DROP CS125 Commercial Filter Valve ...

Page 5: ...lve Rear Inlet Outlet for Single Tank Operation with Manual Bypass No Hard water bypass during regeneration with integrated water shutoff Plugs in Injector Port and Refill Port CS125 20150X500 Softener Valve Side Inlet Outlet for Single Tank Operation Hard water bypass during regeneration with integrated water shutoff Injector CS150 20150X600 Filter Valve Side Inlet Outlet for Single Tank Operatio...

Page 6: ...perform the steps of the regeneration of the softener tank and the outlet water port is shut off For more detailed information about multiplexing DROP valves see our Multiplex ing Filters and Softeners Application Manual The control valves pistons are only available in downflow regeneration The DROP valves include a turbine flow meter that is integral to the valve body The meter is quick to access...

Page 7: ...out making settings and navigating the user interface in your DROP app It is also helpful to know that throughout the app s user interface there are small info icons to help explain all the features in the app The settings that are relevant for a DROP system with the 1 25 and 1 5 valves installed are found on the System Settings page and the Devices Softener or Devices Filter pages in the DROP app...

Page 8: ...lights will rotate according to the direction of the motor movement to get to that position The colors for each position are as follows Position Color Service Green Backwash Purple Brine Draw Light Pink 2nd Backwash Optional Purple Rapid Rinse Light Blue Brine Fill Spring Green Position Color Service Blue Decompress Pink Air Release Lime Backwash Purple Rest Light Yellow Air Chlorine Draw Light Pi...

Page 9: ...acity setting is available in the Devices Softener Advanced page in the App There are two main situations that might cause you to need to change the device configuration on a DROP valve control board The first situation that may cause the need to change the device configura tion is in the case of replacing a board in the system If a generic DROP valve board is used it may need configured to match ...

Page 10: ...same device number Example a softener with multiple tanks Device components of different types must use different device numbers Example a softener and a filter Hold the button for two seconds to accept the selection 6 If the device type was selected to be a Softener in step 3 then one or more LEDs will be lit yellow Repeatedly give a short press on the button to select the correct resin capacity ...

Page 11: ... gpm Brine Line Flow Control Drain Line Flow Controls 2 4 3 3 5 4 5 8 9 10 12 15 20 25 gpm Brine Draw Injector Rates 60 psi see injector charts for details Red 0 p n CS125 0 0 25 gpm White 1 p n CS125 1 0 35 gpm Blue 2 p n CS125 2 0 5 gpm Yellow 3 p n CS125 3 0 63 gpm White 3 p n CS150 3 1 0 gpm Green 4 p n CS150 4 1 7 gpm Blue 5 p n CS150 5 2 0 gpm Distributor Tube Opening 1 32 O D 1 NPS 1 90 O D...

Page 12: ...12 CS125 Injectors OPERATIONS INJECTORS CS150 Injectors ...

Page 13: ...nal valve Brine Line Push Lock Connection To connect the brine tubing to the brine port on the valve 1 Make sure the 3 8 brine tubing is cut squarely on the end 2 Push the tubing into the fitting 7 8 to be sure it is past the O ring seal To release the brine tubing from the brine port on the valve 1 Remove the orange locking clip from the brine port fitting 2 Push in on the gray ring surrounding t...

Page 14: ...Hardwater Bypass 20125X024 Filter Piston No Hardwater Bypass 5 20125X006 Seal Spacer Stack 1 6 20125X007 Water Meter 1 20125X007 P Water Meter Pressure Sensor Combo Optional 7 20125X008 CS125 Valve Body HW 1 20125X013 CS125 Valve Body NHW 8 20125X009 Flow Straightener 1 9 20125X010 Tank Seal O ring 1 10 20125X011 Riser Tube O ring 1 11 CS125 BP 1 25 CS Bypass Optional 1 12 20125X022 1 25 NPT Yoke ...

Page 15: ...ng A 5 No Part No Description Qty 1 20125X012 Push Lock Brine Line fitting 1 2 CS BLFC 3 Brine Line Flow Control 3 0 gpm 1 3 20125X014 Brine Line Flow Control Retainer 1 4 20125X015 Red Locking Clip 1 5 20125X025 Optional Brine Plug for Filter Valves 1 ...

Page 16: ...ol 10 gpm CS DLFC 12 Drain Line Flow Control 12 gpm CS DLFC 15 Drain Line Flow Control 15 gpm CS DLFC 20 Drain Line Flow Control 20 gpm CS DLFC 25 Drain Line Flow Control 25 gpm 2 20125X016 DLFC Retainer 1 3 20017X284 1 1 NPT Drain Line Elbow 1 4 CS125 0 Red 0 Injector with screen and cap CS125 1 CS125 1 White 1 Injector with screen and cap CS125 CS125 2 Blue 2 Injector with screen and cap CS125 C...

Page 17: ...23 Filter Piston Hardwater Bypass 20125X024 Filter Piston No Hardwater Bypass 5 20125X006 Seal Spacer Stack 1 6 20125X007 Water Meter 1 20125X007 P Water Meter Pressure Sensor Combo Optional 7 20150X001 CS150 Valve Body HW 1 20150X003 CS150 Valve Body NHW 8 20125X010 Tank Seal O ring 1 9 20150X002 Riser Tube O ring 1 10 20150X004 1 5 NPT threaded couplers 1 DRAWING A Pg _____ DRAWING B Pg _____ DR...

Page 18: ...3 gpm CS DLFC 3 5 Drain Line Flow Control 3 5 gpm CS DLFC 4 Drain Line Flow Control 4 gpm CS DLFC 5 Drain Line Flow Control 5gpm CS DLFC 8 Drain Line Flow Control 8 gpm CS DLFC 9 Drain Line Flow Control 9 gpm CS DLFC 10 Drain Line Flow Control 10 gpm CS DLFC 12 Drain Line Flow Control 12 gpm CS DLFC 15 Drain Line Flow Control 15 gpm CS DLFC 20 Drain Line Flow Control 20 gpm CS DLFC 25 Drain Line F...

Page 19: ...ng B 5 No Part No Description Qty 1 20125X012 Push Lock Brine Line fitting 1 2 CS BLFC 3 Brine Line Flow Control 3 0 gpm 1 3 20125X014 Brine Line Flow Control Retainer 1 4 20125X015 Red Locking Clip 1 5 20125X025 Optional Brine Plug for Filter Valves 1 ...

Page 20: ...t No Description Qty 1 CS150 3 White 3 Injector with screen cap CS150 1 CS150 4 Green 4 Injector with screen cap CS150 CS150 5 Blue 5 Injector with screen cap CS150 20150X005 Brine Injector Plug for Filters with screen and cap 2 20125X015 Red Locking Clip 1 ...

Page 21: ... 1 2 20125X018 Commercial Slide Cover 1 3 20125X019 Geared Piston Motor 1 4 EVB 029 Commercial DROP control board 1 5 20125X020 Optical Position Endocer 1 6 20125X021 Commercial Power Head Backplate 1 7 20125X027 1 2 Hole Cord Grip 1 8 20018X125 12VDC Power Supply 2 5mm x 5 5mm Barrel Center Positive 2 000mA 1 ...

Page 22: ...22 VALVE BODY FLOW DIAGRAMS Untreated water bypassing during regeneration piston Service Outlet Shutoff Note Brine Piston for Softeners only ...

Page 23: ...23 VALVE BODY FLOW DIAGRAMS Backwash Downflow Brine ...

Page 24: ...24 VALVE BODY FLOW DIAGRAMS Rinse Brine Fill ...

Page 25: ...25 VALVE BODY FLOW DIAGRAMS Outlet water shutoff during regeneration piston Service Outlet Shutoff Note Brine Piston for Softeners only ...

Page 26: ...26 VALVE BODY FLOW DIAGRAMS Backwash Downflow Brine ...

Page 27: ...27 VALVE BODY FLOW DIAGRAMS Rinse Brine Fill ...

Page 28: ...unit has not always been operated within the factory recom mended temperature limits and at a water pressure not exceeding 125 psi during storage use operation accident or alteration light ning flooding or other environmental conditions To any failure or malfunction resulting from failure to operate the system with potable water free to circulate at all times and free of damaging water sediment or...

Page 29: ......

Page 30: ......

Page 31: ...nd improvements to products and or to this document at any time without notice Purchasers should obtain the latest relevant information on Chandler Systems Inc products before placing orders Information in this document supersedes and replaces information previously supplied in any prior versions of this document ...

Page 32: ...Copyright Chandler Systems Inc DROP is a product of Chandler Systems Inc All rights reserved Valve Commercial 0421TV ...

Reviews: