Maintenance

 

WARNING:  Before doing any maintenance be sure unit is unplugged.

Remove Media Frame

To remove the media frame, fi rst remove the two screws located at 
the top of the frame.  Press down at the top center of the unit, near the 
media frame, until it unsnaps from the media frame.  See Fig. 4.

Drain Unit

To drain the unit, remove the media frame and remove the rubber 
drain stopper from inside the bottom of the unit by pulling it out of 
the drain hole.  The unit should be drained periodically to keep the 
water fresh.  We recommend draining the unit once a week.  Drain the 
water from the unit when it will not be used for an extended period.

Cooler Installation

Install Casters

NOTE:  Casters are located inside unit.  These must be removed before starting unit.  See the in-
structions below for removing the back media frame.

This unit comes equipped with 4 stem casters; 2 locking and 2 non-locking.  Before operation turn the unit 
on its side and press the stem casters into the corner holes.  Install the locking caster on one side of the 
unit and the non-locking casters on the opposite side.

Operation

Fill With Water

Open the water access door by pressing fi rmly at the top of the door to 
unlatch it (see fi g. 1).  Fill with a pitcher or water hose.  Do Not Overfi ll.  
Close the access door, pressing fi rmly at the top of the door until it latches 
close.

Water Level Indicator

On the front of the unit there is a window to view the level of water in the 
unit (see fi g. 2).  The red pointer of the indicator will be in the full position 
with water near the top of the reservoir.  As the water level is decreased 
in the unit, the indicator will fall in the window until it reaches the Low 
indicator.   Fill unit with water when low.

Fan Operation

This unit has two separate switches, One for the fan and one for the pump.  
See fi gure 3.  The fan switch has four positions:  Off, 1, 2 and Max.  Turn 
the fan knob to position “1” to start the unit in low speed, “2” for 
middle speed, and “Max” for High speed.  Turn knob to “Off” to turn 
off the fan.

Pump / Cooler Operation

To operate this unit as an evaporative cooler, the unit must be fi lled 
with water and the pump powered on.  Turn the pump knob to “ON” to 
activate pump.  To operate the unit as a fan only, turn the pump knob 
to “OFF”.

Note:  Make sure to turn off both the fan and pump when not in use.

2

Water 
Access 
Door

Fig. 1

Press Here

Screw

Screw

Fig. 4

Fig. 2

FULL

LOW

WATER

OFF

MA

X

1

2

OFF

O

N

FAN

PUMP

Fig. 3

Summary of Contents for UltraCOOL CP20

Page 1: ...nce WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device 110489 6 1 10 Evaporative Cooling Evaporative cooling is an economical way to cool Air is cooled while being drawn across wet evapora tive media The movement of this fresh cooled air over the skin is what makes it feel cool It is important when using an evaporative cooler in a...

Page 2: ...th Water Open the water access door by pressing firmly at the top of the door to unlatch it see fig 1 Fill with a pitcher or water hose Do Not Overfill Close the access door pressing firmly at the top of the door until it latches close Water Level Indicator On the front of the unit there is a window to view the level of water in the unit see fig 2 The red pointer of the indicator will be in the fu...

Page 3: ...oncooler com This limited warranty applies to the original purchaser only Register your product online at www championcooler com eac onlineregistration eac htm Clean Replace Evaporative Media The evaporative media should be cleaned twice a season or when needed To clean the media rinse with clean water Light scrubbing might be necessary Be careful not to damage media After about 2 years or when it...

Page 4: ...s plugged into a 120V power receptacle Check the fuse or breaker If connected to a GFCI outlet check if it is tripped Replacement Parts No Description CP18 CP20 1 Evaporative Media 110132 4 110132 4 2 Evaporative Media Frame Assembly 110875 1 110875 2 3 Set Of 4 Keepers 110871 110871 4 Pump 110440 1 110440 1 5 Drain Plug 110698 1 110698 1 6 Swivel Casters Non Locking 110822 6 110822 6 7 Swivel Cas...

Page 5: ...egan con el aparato ADVERTENCIA Para reducir el riesgo de incendio o toques eléctricos no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Enfriamiento Por Evaporación El enfriamiento por evaporación es una manera económica de enfriarse El aire se enfría mientras se traza a través de un filtro mojado El movimiento de este aire enfriado fresco s...

Page 6: ...ene con agua usando una jarra o una manguera de jardín No Sobre llene Cierra la puerta presionando firmemente en la tapa de la puerta hasta que trabe Indicador De Nivel De Agua En el frente de la unidad hay una ventana de acceso para ver el nivel de agua en la unidad véase la figura 2 El indicador rojo estará en la posición Full cuando está lleno de agua Cuando el nivel de agua se disminuye en la ...

Page 7: ...itada La presente garantía se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales No cubre daños ocurridos por accidente descuido o abuso por parte del propietario No autorizamos que ninguna otra persona o representante asuma por nosotros cualquier otra o diferente responsabilidad en relación con este producto Términos y Condiciones De La Gara...

Page 8: ... que la unidad está enchufada en un receptáculo de 120 voltios Compruebe el fusible o el cortacircuito Si está conectado con un enchufe de GFCI compruebe si se desconectó Piezas De Repuesto n Descripción CP18 CP20 1 Filtro 110132 4 110132 4 2 Montaje De Armazón Del Filtro 110875 1 110875 2 3 Equipo De 4 Sujetadores 110871 110871 4 Bomba 110440 1 110440 1 5 Tapón De Goma 110698 1 110698 1 6 Rueda G...

Reviews: