Circle the model of your cooler and 
record the serial number below.

Read Carefully All Of This Manual 
Before Installing The Unit

Encierrre con un circulo el modelo de su 
enfriador y escribe el número de série abajo.

Lea Con Cuidado Todo Este Manual Antes De 
Instalar La Unidad

Serial #

Número De Série

Safety Rules

1.  Read instructions carefully.
2.  Electrical hook up should be done by a qualifi ed electrician, so 

that all electrical wiring will conform to your local standards.

3. Always 

DISCONNECT POWER

 and 

UNPLUG

 motor and 

pump inside the cooler before installing or performing any 
maintenance.

4.  Motor and pump have a grounded, molded plug and an automatic 

thermal overload switch which will shut motor off when it 
overheats.  The motor will restart automatically when it cools 
down.

WARNING:

  To reduce the risk of fi re or electric shock, do not 

use this fan with any “solid-state fan speed control device.”

Read And Save These Instructions

Vea el Español en el interior.

110498-3

9-09

www.championcooler.com

Table Of Contents

Safety Instructions .......................................................................1
Installation Instructions ............................................................ 2-3
Electrical Wiring Diagram ...........................................................3
Operation .................................................................................. 3-4
Maintenance Section ....................................................................4
Troubleshooting ...........................................................................5

Warranty .......................................................................................5
Parts List (Down Discharge Units) .......................................... 6-7
Parts List (Side Discharge Units) ............................................. 8-9
Parts List (Up Discharge Units) ........................................... 10-11
Specifi cation Tables 

(Tablas de Especifi caciones)

 .....................12

Instrucciones en Español

 ..................................................... 12-16

Evaporative Cooling

Evaporative cooling is nature’s way of cooling.  When air is moved 
over a wet surface, water is evaporated and heat is absorbed.  When 
stepping out of swimming pool with the wind blowing, evaporative 
cooling makes you feel cool, even though the air may be warm.

This unit works on the same principle.  Air is drawn across wet 
fi lter pads where the air is cooled by evaporation and then circulated 
throughout the building.  It is this combination of cooled air and the 
movement of air over the skin which makes it feel cool.

Unlike refrigeration systems which recirculate the air, an evaporative 
cooler continually brings in fresh air while exhausting old air.  You 
are completely replacing the air every 2 to 4 minutes by opening 
windows or doors or a combination of both.  The air is always fresh, 
not stale, laden with smoke and odors as happens with refrigerated 
air conditioning.

Summary of Contents for AU2C711

Page 1: ...ol en el interior 110498 3 9 09 www championcooler com Table Of Contents Safety Instructions 1 Installation Instructions 2 3 Electrical Wiring Diagram 3 Operation 3 4 Maintenance Section 4 Troublesho...

Page 2: ...unit by threading the chase nip ple into the switch box Run the three switch leads through the nipple and into the switch box and reinstall the junction box Connect the green ground lead to the ground...

Page 3: ...ol button again deactivates this mode The Set temperature the target temperature for control may be altered by repeatedly pressing or holding the Up and Down buttons The LCD will display Set rather th...

Page 4: ...the spout and water delivery tube onto the pump outlet Winter Shut Down Drain water Always drain all of the water out of the cooler and water supply line when not in use for prolonged periods and par...

Page 5: ...nit control box 5 Incorrect wiring be tween wall thermostat and cooler 6 Poor connection to Fan motor terminals 7 Unit control board or wall thermostat faulty 1 Insufficient air exhaust 2 Belt too loo...

Page 6: ...a El Medio Evaporativo Izquierdo 281043 001 281045 001 281044 001 281046 001 30 Water Distributor Housing Caja Del Distribuidor De Agua 281038 001 281033 001 281038 001 281033 001 31 Water Distributor...

Page 7: ...7 110498 3 Replacement Parts Piezas De Repuesto AD1C51 AD2C51 AD1C5112 AD2C5112 AD1C71 AD2C71 AD1C7112 AD2C7112...

Page 8: ...45 002 281044 002 281046 002 29 Media Shield Left Protector Para El Medio Evaporativo Izquierdo 281043 001 281045 001 281044 001 281046 001 30 Water Distributor Housing Caja Del Distribuidor De Agua 2...

Page 9: ...9 110498 3 Replacement Parts Piezas De Repuesto AS1C51 AS2C51 AS1C5112 AS2C5112 AS1C71 AS2C71 AS1C7112 AS2C7112...

Page 10: ...Del Distribuidor De Agua 3D 23 32 Evaporative Media Medio Evaporativo 310118 002 33 Distributor Filter Pad Filtro Del Distribuidor 110120 34 Water Reservoir Bandeja Acumuladora De Agua 281042 35 Tube...

Page 11: ...11 110498 3 Replacement Parts Piezas De Repuesto AU1C7112 AU2C7112...

Page 12: ...l aire viejo Se reemplaza completamente el aire cada 2 a 4 minutos abriendo las ventanas o las puertas o una combinaci n de ambas El aire es siempre fresco no es viciado cargado de humo y olores como...

Page 13: ...encuentra en el interior del panel central v ase Fig 5 Por dentro de la unidad inserte la niple roscada a trav s del agujero de acceso el ctrico Resbale el anillo de estanquidad sobre la niple roscad...

Page 14: ...est funcionando en el modo Cool o Fan cuando presiona el bot n Timer el periodo de retraso se determina cuando el enfriador apagar Si el enfriador est apagada cuando presiona el bot n Timer el per od...

Page 15: ...pecto a cualquier duda o pregunta Cuanto Debe Abrir Las Ventanas Un concepto a menudo entendido mal de enfriamiento por evaporaci n es la cantidad de aire que debe ser agotada Cu nto debe usted abrir...

Page 16: ...ivo no est mojado Filtros obstruidos Agujeros del tubo obs truidos Bomba no funciona 1 Insuficiente salida de aire Problema Causa Posible Remedio Problema Causa Posible Remedio La Localizaci n De Aver...

Reviews: