background image

11

  

REV 75555i-20140110

ENGLISH

 

75555i

OPERATION

Do Not Overload Generator

Capacity

Follow these simple steps to calculate the running and 
starting watts necessary for your purposes. 
1.  Select the electrical devices you plan on running at 

the same time.

2.  Total the running watts of these items. This is 

the amount of power you need to keep your items 
running.

3.  Identify the highest starting wattage of all devices 

identified in step 1. Add this number to the number 
calculated in step 2. Surge wattage is the extra 
burst of power needed to start some electric driven 
equipment. Following the steps listed under “Power 
Management” will guarantee that only one device 
will be starting at a time.

Power Management

Use the following formula to convert voltage and 
amperage to watts:

Volts x Amps = Watts

To prolong the life of your generator and attached 
devices, follow these steps to add electrical load:
1.  Start the generator with no electrical load attached.
2.  Allow the engine to run for several minutes to 

stabilize.

3.  Plug in and turn on the first item. It is best to 

attach the item with the largest load first.

4.  Allow the engine to stabilize.
5.  Plug in and turn on the next item.
6.  Allow the engine to stabilize.
7.  Repeat steps 5-6 for each additional item.

Never exceed the specified capacity when adding 
loads to the generator.

NOTE

Stopping the Engine

1.  Turn off and unplug all electrical loads. Never start 

or stop the generator with electrical devices plugged 
in or turned on.

2.  Let the generator run at no-load for several minutes 

to stabilize internal temperatures of the engine and 
generator.

3.  Turn the Fuel Valve to the “OFF” position.
4.  Let the engine run until fuel starvation has stopped 

the engine. This usually takes a few minutes.

5.  Turn the engine switch to the “Off” position.
6.  Turn the fuel cap lever vent to the “Off” position 

after the generator has cooled down completely.

Important:

 Always ensure that the Fuel Valve and the 

Engine Switch are in the “OFF” position when the 
engine is not in use.

If the engine will not be used for a period of two (2) 
weeks or longer, please see the storage section for proper 
engine and fuel storage.

NOTE

12V DC Outlet

Be sure all electric devices including the lines and plug 
connections are in good condition before connection to 
the generator.

NOTE

Do not start the vehicle while the battery charging cable is 
connected and the generator is running. It will not give the 
battery a boost of power. The vehicle or the generator may 
be damaged. Charge only vented wet lead acid batteries. 
Other types of batteries may burst, causing personal injury 
or damage.

CAUTION

The 12V DC outlet can be used with the supplied charge 
cable and USB charger and other commercially available 
12V DC automotive style plugs.  The DC output is 
unregulated and can damage some products.  Confirm 
your accessory input voltage range is at least 12-21V 
DC.  When using the DC outlet turn the Economy mode 
switch to the “OFF” position.

12V DC Outlet – Battery Charging

1.  Before connecting the battery charging cable to a 

battery that is installed in a vehicle, disconnect the 
vehicle battery ground cable from the negative (–) 
battery terminal.

2.  Plug the battery charging cable into the 12V DC 

receptacle of the generator.

3.  Connect the red (+) battery charger lead to the red 

(+) battery terminal.

4.  Connect the black (–) battery charger lead to the 

black (–) battery terminal.

5.  Start the generator.

Important:

 The 12V DC outlet is ONLY to be used with 

the supplied 12V DC battery charging cable. The 12V 
DC output is unregulated and will damage other 12V 
DC products. When using the 12V DC outlet, turn the 
Economy mode switch to the “OFF” position. Be sure all 
electric devices including the lines and plug connections 
are in good condition before connection to the generator.

Summary of Contents for 75555i

Page 1: ...999 www championpowerequipment com PORTABLE INVERTER GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 75555i 20140110 3100 Max Watts 2800 R...

Page 2: ...Care Team Toll Free at 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 10...

Page 3: ...age 12 Engine Maintenance 12 Oil 12 Spark Plugs 12 Air Filter 13 Cleaning 13 Spark Arrester 13 Adjustments 13 Maintenance Schedule 13 Generator Maintenance 14 Storage 14 Generator Storage 14 Specifica...

Page 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Page 5: ...y hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided...

Page 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can...

Page 7: ...al equipment in the off position and then turn them on for operation Turn electrical equipment off before stopping the generator DO NOT tamper with the governed speed DO NOT modify the generator in an...

Page 8: ...Cap Remove to add fuel 2 Recoil Starter Used to start the engine 3 Power Panel 4 Muffler 5 Maintenance Cover 6 Never Flat Wheels 7 Carrying Handle Inverter CONTROLS AND FEATURES Parts Included Your 75...

Page 9: ...ctrical overload 9 Oil Warning Light Check oil level when this light turns on Engine will not run when indicator is lit 10 Overload Indicator Light This light turns ON when the generator is overloaded...

Page 10: ...cover 5 Check engine oil level daily and add as needed 3 Remove oil fill cap dipstick to add oil 4 Add 0 6 qt 0 6 L of oil and replace oil fill cap dipstick DO NOT OVERFILL The recommended oil type is...

Page 11: ...fuel Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 6 4 mm in below the top of the tank to allow for fuel expansion DO NOT pump...

Page 12: ...bed of a truck regular flat or otherwise under staircases stairwells next to walls or buildings or in any other location that will not allow for adequate cooling of the generator and or the muffler DO...

Page 13: ...will be connected to a building electrical system consult your local utility company or a qualified electrician Connections must isolate generator power from utility power and must comply with all ap...

Page 14: ...on 6 Turn the fuel cap lever vent to the Off position after the generator has cooled down completely Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the...

Page 15: ...to remove the plug 4 Remove the spark plug 5 Inspect the electrode on the plug It must be clean and not worn to produce the spark required for ignition 6 Make certain the spark plug gap is 0 7 0 8 mm...

Page 16: ...frequently when operating in adverse conditions Contact our help line at 1 877 338 0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenanc...

Page 17: ...attach the spark plug 11 Store the unit in a clean dry place out of direct sunlight MAINTENANCE AND STORAGE Generator Maintenance Make certain that the generator is kept clean and stored properly Only...

Page 18: ...FD 33 Displacement 171cc Type 4 Stroke OHV Start Type Recoil Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 02...

Page 19: ...9 5 8 7 5 5 21752 81 7 3257 5 2 6 57 7 50 1 3 5 7 50 1 2 9 6 67 33 1 02725 63 5 1 3 8 6723 6 5 2 8 5 1 5 7 U 7 8 5 1 2 7 5 1 52 1 7 1 5 725 1 1 5 37 2 68 2 2 2 2 5 5 5 5 7 81 7 5 5 51 7 21 0 7 67 2 2...

Page 20: ...17 REV 75555i 20140110 ENGLISH 75555i Parts Diagram SPECIFICATIONS...

Page 21: ...2 006 Flange Nut M14 1 5 1 58 83 191100 01 Rotor Assembly 1 59 1 5789 0645 Flange Bolt M6 45 4 60 83 191200 10 Stator Assembly Cu DC12V CSA 1 61 83 190002 01 End Cover Mortor 1 Part Number Description...

Page 22: ...77 76 75 74 73 48 49 50 51 52 54 56 57 58 59 62 61 63 64 66 68 69 72 33 32 29 30 28 26 25 47 46 45 44 43 42 41 40 38 37 36 96 93 100 99 92 91 90 89 88 24 23 21 20 19 18 17 16 15 14 13 12 1 2 3 4 5 6...

Page 23: ...her Drain Bolt 10 16 1 5 1 51 2 08 037 Bolt Drain M10 1 25 25 1 52 83 030009 01 Gasket Cylinder Head 1 Part Number Description Qty 53 2 04 003 Dowel Pin 10 14 2 54 83 040006 01 Valve Exhaust 1 55 83 0...

Page 24: ...shuts down during operation Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Gene...

Page 25: ...labour if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Page 26: ...ject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRAN...

Page 27: ...ll be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted...

Page 28: ...talled along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to s...

Reviews: