REV 75536i-20130729
6
75536i
ENGLISH
Power Panel
(1) Fuel Valve Knob
(2) Choke
(3) Economy Control Switch
(4) Ground Terminal – Consult an electrician for local
grounding regulations.
(5) 12V DC Outlet*
(6) Circuit Breaker (Push button) – Protects the
generator against electrical overload.
(7) 120 Volt AC, 20 Amp Duplex
(NEMA 5-20R) –
May be used to supply electrical power for the
operation of 120 Volt AC, 20 Amp, single phase
60 Hz electrical loads.
CONTROLS AND FEATURES
12
8
3
4
5
6
2
1
(8) 120 Volt AC, 30 Amp Receptacle (NEMA TT-30R)
–
May be used to supply electrical power for the
operation of 120 Volt AC, 30 Amp, single phase
60 Hz electrical loads.
(9) Oil Warning Light – Check oil level when this light
turns on. Engine will not run when indicator is lit.
(10) Overload Indicator Light – This light turns ON
when the generator is overloaded and will cut
power to the receptacles.
(11) Output Light – Remains ON during normal
operating conditions. Shuts OFF when generator is
overloaded.
(12) Engine Switch
*Warning: Do not operate a device while it is plugged into the 12V DC outlet. Prolonged exposure to engine exhaust can cause
serious injury or death. While charging a device do no place on the exhaust side of the generator. Extreme heat caused by exhaust
can damage the device, and cause a potential fire hazard.