SAFETy RULES

Generator exhaust contains carbon monoxide, a 
colourless, odourless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.

DANGER CARBON MONOXIDE:

 using a generator 

indoors

 CAN KILL YOU IN MINUTES

.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, 
damaged or frayed.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to 
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in 
damp areas and areas containing conductive 
material such as metal decking.
Use approved transfer equipment to isolate 
generator from your electric utility and notify your 
utility company before connecting your generator to 
your power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 
cannot contact the plug.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 
occur on contact. 
Combustible material can catch fire on contact.

DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all 
sides to ensure adequate cooling.
Maintain at least 5 ft. (1.5 m) of clearance from 
combustible materials.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

SAFETy RULES

Improper treatment or use of the generator can 
damage it, shorten its life and void your warranty.

Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, 
dust, or dirt.
DO NOT allow any material to block the cooling 
slots.
If connected devices overheat, turn them off and 
disconnect them from the generator.
DO NOT use the generator if:

 

– Electrical output is lost

 

– Equipment sparks, smokes or emits flames

 

– Equipment vibrates excessively

CAUTION

Operation of this equipment may create sparks that 
can start fires around dry vegetation.

A spark arrester may be required. The operator 
should contact local fire agencies for laws or 
regulations relating to fire prevention requirements.

WARNING

Rapid retraction of the starter cord will pull hand and 
arm towards the engine faster than you can let go. 
Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  
Broken bones, fractures, bruises or sprains could 
result.

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to avoid 
kickback.
DO NOT start or stop the engine with electrical 
devices plugged in.

WARNING

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it.

DO NOT overload the generator.
Start the generator and allow the engine to stabilize 
before connecting electrical loads.
Connect electrical equipment in the off position, 
and then turn them on for operation.
Turn electrical equipment off before stopping the 
generator.
DO NOT tamper with the governed speed. 
DO NOT modify the generator in any way.

CAUTION

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can 
result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Medical and Life Support Uses.

In case of emergency, call emergency services.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals that are known to cause serious health 
problems and even death.

WARNING

Summary of Contents for 73001i-DF (EU)

Page 1: ... d e dos años G a r a n t í a l i m i t a d a d e dos años T h ree Year Limited Warran t y T h ree Year Limited Warran t y G a r a n t í a l i m i t a d a de un año G a r a n t í a l i m i t a d a de un año Garantie li m i t é e d e t r o i s a n s Garantie li m i t é e d e t r o i s a n s T wo Year Limited Warrant y G a rantie limitée de deux a n s T wo Year Limited Warrant y G a rantie limitée d...

Page 2: ...rve the right to change alter or improve the product and this manual without prior notice Please familiarize yourself with the following symbols The safety symbol and key words are safety warnings Follow all safety messages to avoid accidents or injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the sa...

Page 3: ...re dust or dirt DO NOT allow any material to block the cooling slots If connected devices overheat turn them off and disconnect them from the generator DO NOT use the generator if Electrical output is lost Equipment sparks smokes or emits flames Equipment vibrates excessively CAUTION Operation of this equipment may create sparks that can start fires around dry vegetation A spark arrester may be re...

Page 4: ...fire prevention requirements La operación de este equipo puede originar chispas que pueden crear incendios cerca de la vegetación seca Es posible que se requiera un parachispas El operador deberá comunicarse con los organismos locales encargados de combatir incendios para conocer las leyes o reglamentos relacionados con los requisitos para prevenir incendios FOR USE IN A WEATHER PROTECTED AREA ONL...

Page 5: ...d replace oil fill cap dipstick DO NOT OVERFILL 5 Check engine oil level daily and add as needed The recommended oil type is 10W 30 automotive oil NOTE Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the generator as a result of failure to follow these instructions will void your warranty CAUTION Ad...

Page 6: ...g and storing turn off the cylinder valve and fuel valve and disconnect the cylinder Plug the outlet usually by a plastic protective cap if one is available Keep cylinders away from heat and ventilated when in a vehicle CAUTION Connecting LPG Cylinder Cont d Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock A ground terminal connected to th...

Page 7: ...l or LPG To select the desired fuel source simply rotate the selector switch to the fuel symbol on the panel Turn the fuel selector switch to the 12 o clock vertical position for LPG operation A Turn the fuel selector switch to the 3 o clock horizontal position for petrol operation B A B LPG GAS When the battery switch is in the ON position the switch will light up if the battery is sending out a ...

Page 8: ... by pouring warm water over the top of the tank Economy Control Switch The Economy Control switch can be activated in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output allowing the engine speed to idle during periods of non use The engine speed returns to normal when an electrical load is connected When the economy switch is off the eng...

Page 9: ...fuel starvation has stopped the engine This usually takes a few minutes 6 Press the ignition switch to the OFF position 7 Turn battery switch to the Off Position Important Always ensure that the fuel valve and the ignition switch are in the OFF position when the engine is not in use When turning off the generator after LPG operation make sure the LPG cylinder knob is in the fully closed position N...

Page 10: ...he dipstick to check oil level DO NOT screw in the dipstick while checking NOTE 8 Reinstall the maintenance cover and tighten the cover screws 9 Dispose of used oil at an approved waste management facility GFCI Your generator is equipped with two 2 Ground Fault Circuit Interrupter GFCI duplexes In the event of a ground fault a GFCI trips automatically to stop the flow of electricity and prevent se...

Page 11: ...the generator Water can enter the generator through the cooling slots and damage the generator windings CAUTION Disconnect the Battery 1 Remove the battery panel cover 2 Remove the protective cover from the black negative battery lead 3 Disconnect the black negative lead from the black negative terminal on the battery and store the cap screw and nut 4 Repeat steps 1 2 for the red positive battery ...

Page 12: ...sition When storing the generator for extended periods of time make sure that the ignition switch the fuel valve and the battery switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER Troubleshooting Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load f...

Page 13: ...Off Yes Wheels Yes Wheel Type Solid Wheel Diameter 5 5 in CE Approved Yes 73001I DF EU WIRING DIAGRAM DC COIL DC DIODE _ DC12V CIRCUIT BREAKER 8A Y CONTROL UNIT PORTFIRE ECO SW EARTH TERMINAL OIL LEVEL SW SPARKING PLUG STOP SW L W G B Y R YELLOW BLACK BLUE GREEN RED WHITE Br WHITE BLUE GREEN YELLOW WHITE GREEN BROWN BLACK WHITE B W W L G Y W G GENERATOR ENGINE G RECEPTACLE AC COIL SUB COIL W B W O...

Page 14: ...82 81 56 57 58 59 60 62 64 65 66 67 70 69 71 72 74 76 77 80 34 33 30 31 29 27 26 55 52 46 45 44 43 42 41 39 38 37 25 24 22 21 20 19 18 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 40 35 68 86 87 88 91 92 63 5 5 28 36 111 110 109 75 73 78 79 36 49 50 51 61 48 104 96 97 98 99 100 101 102 103 105 106 107 54 53 47 23 108 12 25 32 ...

Page 15: ...8 0 2 1 8 5 M t u N e g a C 0 1 0 2 0 2 0 4 41 83 200701 03 2 Handle Left Blac e R 1 1 0 0 2 1 1 5 1 2 1 1 k 1 e l c a t p e c 1 k c a l B t f e L t e k c a r B 2 1 0 4 0 7 0 0 2 3 8 2 4 8 4 1 x 4 M w e r c S 4 1 4 0 9 1 8 1 2 2 1 0 1 k c a l B e g n a l F 4 M t u N k c o L 1 4 0 1 7 7 1 6 1 3 2 1 1 t h g i R r e t r o p p u S 5 0 0 0 6 1 0 2 3 8 3 4 2 n o t t u B h s u P r e k a e r B A 5 1 C A 5...

Page 16: ...Page intentionally left blank Page intentionally left blank ...

Page 17: ......

Reviews: