MAINTENANCE AND STORAGE

Air Filter

1.  Remove the maintenance cover.
2.  Locate the air filter plastic cover. 
3.  Unsnap the locking hinge on the cover.
4.  Remove the old filter. 
5.  Place the new filter in the assembly.
6.  Re-snap the hinge on the air filter cover.
7.  Reinstall the maintenance cover and tighten the 

cover screw securely.

Use a damp cloth to clean exterior surfaces of the 
generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris 
from the generator.

Cleaning

DO NOT spray generator with water.

CAUTION

Water can contaminate the fuel system.

Adjustments

The air-fuel mixture is not adjustable. Tampering with 
the governor can damage your generator and your 
electrical devices and will void your warranty. 

Maintenance Schedule

Follow the service intervals indicated in the following 
maintenance schedule. 
Service your generator more frequently when operating 
in adverse conditions. 

Spark Arrester

1.  Allow the engine to cool completely before servicing 

the spark arrester.

2.  Remove the two screws holding the cover plate 

which retains the end of the spark arrester to the 
muffler.

3.  Remove the spark arrester screen.
4.  Carefully remove the carbon deposits from the spark 

arrester screen with a wire brush.

5.  Replace the spark arrester if it is damaged.
6.  Position the spark arrester in the muffler and attach 

with the two screws.

Failure to clean the spark arrester will result in 
degraded engine performance.

CAUTION

MAINTENANCE AND STORAGE

Generator Maintenance

Make certain that the generator is kept clean and stored 
properly. Only operate the unit on a flat, level surface in 
a clean, dry operating environment. DO NOT expose the 
unit to extreme conditions, excessive dust, dirt, moisture 
or corrosive vapours.
Use a damp cloth to clean exterior surfaces of the 
generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris 
from the generator. 
Inspect all air vents and cooling slots to ensure that they 
are clean and unobstructed.

DO NOT use a garden hose to clean the generator.

Water can enter the generator through the cooling 
slots and damage the generator windings.

CAUTION

Disconnect the Battery

1.  Remove the battery panel cover.
2.  Remove the protective cover from the black/negative 

battery lead.

3.  Disconnect the black/negative lead from the black/

negative terminal on the battery and store the cap 
screw and nut.

4.  Repeat steps 1-2 for the red/positive battery lead.
5.  Store the battery in a cool, dry place.

A Float Charger will maintain the battery condition 
over long storage periods.

NOTE

Charge the Battery

For a generator equipped with batteries for electric 
starting, proper battery maintenance and storage should 
be followed. An automatic battery charger (included) 
with automatic charging capability should be used to 
charge the battery. Maximum charging rate should not 
exceed 1.5 amps. Follow the instructions included with 
the battery charger. The battery should be fully charged 
at least once per month.

Generator Battery

This product is equipped with an automatic battery 
charging circuit. The battery will receive charging 
voltage when the engine is running. The battery will 
maintain a proper charge if the unit is used on a regular 
basis (about once every two weeks). If it is used less 
frequently, the battery should be connected to a trickle 
charger (included) or battery maintainer to keep the 
battery properly charged. If the battery is not able to 
start the engine, it can be started by manually pulling 
the engine recoil cord. If the battery voltage is extremely 
low, the charging circuit may not be able to re-charge 
the battery. In this case, the battery must be connected 
to a standard automotive style battery charger for  
re-charging before it can be used.

*To be performed by knowledgeable, experienced owners or 
Champion Power Equipment certified dealers.

Every 8 hours or daily

Check oil level

Clean around air intake and muffler

Check hoses for leaks

First 5 hours

Change oil

Every 50 hours or every season

Clean air filter

Change oil if operating under heavy load or in hot environments

Every 100 hours or every season

Change oil

Clean/Adjust spark plug

Check/Adjust valve clearance*

Clean spark arrester

Clean fuel tank and filter*

Every 250 hours

Clean combustion chamber*

Every 3 years

Replace fuel line and LPG hose

Summary of Contents for 73001i-DF (EU)

Page 1: ... d e dos años G a r a n t í a l i m i t a d a d e dos años T h ree Year Limited Warran t y T h ree Year Limited Warran t y G a r a n t í a l i m i t a d a de un año G a r a n t í a l i m i t a d a de un año Garantie li m i t é e d e t r o i s a n s Garantie li m i t é e d e t r o i s a n s T wo Year Limited Warrant y G a rantie limitée de deux a n s T wo Year Limited Warrant y G a rantie limitée d...

Page 2: ...rve the right to change alter or improve the product and this manual without prior notice Please familiarize yourself with the following symbols The safety symbol and key words are safety warnings Follow all safety messages to avoid accidents or injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the sa...

Page 3: ...re dust or dirt DO NOT allow any material to block the cooling slots If connected devices overheat turn them off and disconnect them from the generator DO NOT use the generator if Electrical output is lost Equipment sparks smokes or emits flames Equipment vibrates excessively CAUTION Operation of this equipment may create sparks that can start fires around dry vegetation A spark arrester may be re...

Page 4: ...fire prevention requirements La operación de este equipo puede originar chispas que pueden crear incendios cerca de la vegetación seca Es posible que se requiera un parachispas El operador deberá comunicarse con los organismos locales encargados de combatir incendios para conocer las leyes o reglamentos relacionados con los requisitos para prevenir incendios FOR USE IN A WEATHER PROTECTED AREA ONL...

Page 5: ...d replace oil fill cap dipstick DO NOT OVERFILL 5 Check engine oil level daily and add as needed The recommended oil type is 10W 30 automotive oil NOTE Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the generator as a result of failure to follow these instructions will void your warranty CAUTION Ad...

Page 6: ...g and storing turn off the cylinder valve and fuel valve and disconnect the cylinder Plug the outlet usually by a plastic protective cap if one is available Keep cylinders away from heat and ventilated when in a vehicle CAUTION Connecting LPG Cylinder Cont d Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock A ground terminal connected to th...

Page 7: ...l or LPG To select the desired fuel source simply rotate the selector switch to the fuel symbol on the panel Turn the fuel selector switch to the 12 o clock vertical position for LPG operation A Turn the fuel selector switch to the 3 o clock horizontal position for petrol operation B A B LPG GAS When the battery switch is in the ON position the switch will light up if the battery is sending out a ...

Page 8: ... by pouring warm water over the top of the tank Economy Control Switch The Economy Control switch can be activated in order to minimize fuel consumption and noise while operating the unit during times of reduced electrical output allowing the engine speed to idle during periods of non use The engine speed returns to normal when an electrical load is connected When the economy switch is off the eng...

Page 9: ...fuel starvation has stopped the engine This usually takes a few minutes 6 Press the ignition switch to the OFF position 7 Turn battery switch to the Off Position Important Always ensure that the fuel valve and the ignition switch are in the OFF position when the engine is not in use When turning off the generator after LPG operation make sure the LPG cylinder knob is in the fully closed position N...

Page 10: ...he dipstick to check oil level DO NOT screw in the dipstick while checking NOTE 8 Reinstall the maintenance cover and tighten the cover screws 9 Dispose of used oil at an approved waste management facility GFCI Your generator is equipped with two 2 Ground Fault Circuit Interrupter GFCI duplexes In the event of a ground fault a GFCI trips automatically to stop the flow of electricity and prevent se...

Page 11: ...the generator Water can enter the generator through the cooling slots and damage the generator windings CAUTION Disconnect the Battery 1 Remove the battery panel cover 2 Remove the protective cover from the black negative battery lead 3 Disconnect the black negative lead from the black negative terminal on the battery and store the cap screw and nut 4 Repeat steps 1 2 for the red positive battery ...

Page 12: ...sition When storing the generator for extended periods of time make sure that the ignition switch the fuel valve and the battery switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER Troubleshooting Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load f...

Page 13: ...Off Yes Wheels Yes Wheel Type Solid Wheel Diameter 5 5 in CE Approved Yes 73001I DF EU WIRING DIAGRAM DC COIL DC DIODE _ DC12V CIRCUIT BREAKER 8A Y CONTROL UNIT PORTFIRE ECO SW EARTH TERMINAL OIL LEVEL SW SPARKING PLUG STOP SW L W G B Y R YELLOW BLACK BLUE GREEN RED WHITE Br WHITE BLUE GREEN YELLOW WHITE GREEN BROWN BLACK WHITE B W W L G Y W G GENERATOR ENGINE G RECEPTACLE AC COIL SUB COIL W B W O...

Page 14: ...82 81 56 57 58 59 60 62 64 65 66 67 70 69 71 72 74 76 77 80 34 33 30 31 29 27 26 55 52 46 45 44 43 42 41 39 38 37 25 24 22 21 20 19 18 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 40 35 68 86 87 88 91 92 63 5 5 28 36 111 110 109 75 73 78 79 36 49 50 51 61 48 104 96 97 98 99 100 101 102 103 105 106 107 54 53 47 23 108 12 25 32 ...

Page 15: ...8 0 2 1 8 5 M t u N e g a C 0 1 0 2 0 2 0 4 41 83 200701 03 2 Handle Left Blac e R 1 1 0 0 2 1 1 5 1 2 1 1 k 1 e l c a t p e c 1 k c a l B t f e L t e k c a r B 2 1 0 4 0 7 0 0 2 3 8 2 4 8 4 1 x 4 M w e r c S 4 1 4 0 9 1 8 1 2 2 1 0 1 k c a l B e g n a l F 4 M t u N k c o L 1 4 0 1 7 7 1 6 1 3 2 1 1 t h g i R r e t r o p p u S 5 0 0 0 6 1 0 2 3 8 3 4 2 n o t t u B h s u P r e k a e r B A 5 1 C A 5...

Page 16: ...Page intentionally left blank Page intentionally left blank ...

Page 17: ......

Reviews: