201160 - 12,000W ELEcTRic START GENERATOR
ASSEMbLY
17
NOTicE
The recommended oil type for typical use is
5W-30
automotive oil
. However, using the listed conventional oils
shown in the “Recommended Engine Oil Type” chart may be
used for typical use including the first 5 hours of the break-in
run time period of the engine.
If running generator in extreme temperatures, refer to the
“Recommended Engine Oil Type” chart.
-20
0
20
40
60
Ambient temperature
Recommended Engine Oil Type
80
100
120
-28.9
°F
°C
-17.8
-6.7
4.4
15.6
26.7
37.8
48.9
10W-30
5W-30 Full Synthetic
10W-40
5W-30
1. Place the generator on a flat, level surface.
2. Open the engine access cover.
3. Remove yellow cap on cylinder head cover on left side of
engine.
4. Using funnel fill to full mark on dipstick. DO NOT OVERFILL.
Volume for first use or oil change without oil filter change:
33.8 fl. oz. (1000 ml).
Volume after oil and oil filter change: 44 fl. oz. (1300 ml).
5. Pull out dipstick and check engine oil level. Add as needed.
DO NOT OVERFILL.
6. Replace dipstick.
7. Close engine access cover.
NOTicE
Check oil level often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
cAUTiON
This engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.
NOTicE
The first 5 hours of run time are the break-in period for the
unit. During the break in period stay at or below 50% of the
running watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the load will also
cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTicE
Synthetic oil may be used after the 5 hour initial break-in
period. Using synthetic oil does not decrease the recommended
oil change interval. Full synthetic 5W-30 oil will aid in starting
in cold ambient < 41º F (5º C) temperatures.