3
ENGLISH
75500i
OPERATION
Paralleling two 3100W or larger inverters
1 . Inverters to be turned off and all electrical loads
disconnected before installing parallel kit .
2 . Align the inverters in the same direction in a “V”
configuration at a minimum of 18 in . [45cm] apart .
3 . Clamp the parallel kit to the left handle of the
inverter on the left of the “V” .
4 . On each inverter, remove the connector end cap and
insert the RED power lead into the RED receptacle
and the BLACK power lead into the BLACK
receptacle .
5 . On each inverter, connect the grounding wire to the
grounding terminal on the inverter .
6 . Start engine of both inverters according to inverter
Owner’s Manual . Observe the green output
indicator light on both inverter panels . The light
will blink during start up and will be solid when
loads may be connected .
7 . Connect devices to parallel or inverter panels up to
the receptacles rated amperage . Never exceed the
specified capacity of the receptacle .
8 . Follow the instructions in the inverter Owner’s
Manual for turning off the inverter .
Paralleling one 3100W or larger inverter
and one 2000W inverter
1 . Inverters to be turned off and all electrical loads
disconnected before installing parallel kit .
2 . Align the inverters in the same direction in a “V”
configuration at a minimum of 18 in . [45cm] apart .
3 . Clamp the parallel kit to the left handle of the
inverter on the left of the “V” .
4 . Connect the 3100W or larger inverter as shown
above .
5 . Connect the 2000W inverter by removing the
adapter connectors from the back of the parallel kit .
6 . Remove the connector end cap and insert the RED
power lead into the RED adapter connector and
then into the RED receptacle and the BLACK power
lead into the BLACK adapter connector and then
into the BLACK receptacle .
7 . Start engine of both inverters according to inverter
Owner’s Manual . Observe the green output
indicator light on both inverter panels . The light
will blink during start up and will be solid when
loads may be connected .
8 . Connect electrical loads to parallel or inverter
panels up to the receptacles rated amperage . Never
exceed the specified capacity of the receptacle .
9 . Follow the instructions in the inverter Owner’s
Manual for turning off the inverter .
This kit is intended for the use with Champion Power
Equipment inverters with a least one inverter being
3100W or larger, and with the ability to parallel . Please
refer to your inverter Owner’s Manual for safety rules,
start up, and shut down procedures, specifications, and
troubleshooting .
If not spaced apart, the exhaust heat from one unit
may discolor or melt the plastic on the other unit .
WARNING