Power Panel

(1)  120 Volt, 30 Amp Twist-Lock Receptacle – (Nema 

L5-30R) This receptacle powers 120 Volt AC, 60 
Hz, single phase loads .

(2)  Circuit Breaker 30 Amp – Protects against 

electrical overload .

(3)  120 Volt, 50 Amp Receptacle  

(NEMA 5-50R) – May be used to supply electrical 
power for the opertaion of 120 Volt AC, single 
phase 60 Hz electrical loads .

(4)  Circuit Breaker 50 Amp – Protects against 

electrical overload .

CONTROLS AND FEATuRES

1

4

2

3

Generators produces powerful voltage .

DO NOT touch bare wires or receptacles .

DO NOT use electrical cords that are worn, damaged 

or frayed .

DO NOT operate generator in wet weather .

DO NOT allow children or unqualified persons to 

operate or service the generator

Always inspect your parallel kit, outlets, wires, parts 

prior to use .

DO NOT use if any part or wire is frayed, exposed, or 

broken .

DANGER

Summary of Contents for 75500i

Page 1: ...R PARALLEL KIT SAVE THESE INSTRuCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 75500i 20151110 OWNER S MANUAL OPERATING INSTRUCTIONS 75500i MODEL NUMBER G a r a n t...

Page 2: ...store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Care T...

Page 3: ...rger inverter and one 2000W inverter 3 Warranty 4 Warranty Qualifications 4 Repair Replacement Warranty 4 Do Not Return The Unit To The Place Of Purchase 4 Warranty Exclusions 4 Normal Wear 4 Installa...

Page 4: ...and this document at any time without prior notice Since CPE CET highly value how our products are designed manufactured operated and are serviced and also highly value your safety and the safety of...

Page 5: ...ingle phase 60 Hz electrical loads 4 Circuit Breaker 50 Amp Protects against electrical overload Controls and Features 1 4 2 3 Generators produces powerful voltage DO NOT touch bare wires or receptacl...

Page 6: ...Align the inverters in the same direction in a V configuration at a minimum of 18 in 45cm apart 3 Clamp the parallel kit to the left handle of the inverter on the left of the V 4 Connect the 3100W or...

Page 7: ...if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical...

Page 8: ...5 ENGLISH 75500i Parts Diagram Parts 1 2 3 4 5 6 7 8 10 3 12 11 4 9 13...

Page 9: ...embly M4 14 8 5 1 6177 1 04 1 Flange lock nut M4 4 6 5 1120 023 Receptacle L5 30R CSA 1 7 5 1220 300 30 Amp circuit breaker flip lever 1 8 1 9074 4 0306 1 screw washer assembly M3 6 4 9 5 1220 500 50...

Reviews: