Champion Power Equipment 41331 Owner'S Manual And Operating Instructions Download Page 16

Operation 

12                                                                                              Rev 41331-20110330 English

  NOTE 

Connecting a generator to your electric utility 
company’s power lines or to another power 
source may be against the law. In addition this 
action, if done incorrectly, could damage your 
generator and appliances and could cause 
serious injury or even death to you or a utility 
worker who may be working on nearby power 
lines. If you plan to run a portable electric 
generator during an outage, please notify your 
electric utility company immediately and 
remember to plug your appliances directly into 
the generator. Do not plug the generator into 
any electric outlet in your home. Doing so could 
create a connection to the utility company power 
lines. You are responsible for ensuring that your 
generator’s electricity does not feed back into the 
electric utility power lines.

 

 

If the generator will be connected to a building 
electrical system, consult your local utility 
company or a qualified electrician. Connections 
must isolate generator power from utility power 
and must comply with all applicable laws and 
codes.

 

 

Stopping the Engine 

1.

 

Turn off and unplug all electrical loads. 

Never start or stop the generator with 

electrical devices plugged in or turned 

on. 

2.

 

Let the generator run at no-load for 

several minutes to stabilize internal 

temperatures of the engine and 

generator. 

3.

 

Turn the ignition switch to the “Off” 

position. 

4.

 

Turn the fuel valve to the “Off” position. 

Do Not Overload Generator

 

Capacity

 

Follow these simple steps to calculate the 

running and starting watts necessary for 

your purposes.  

1.

 

Select the electrical devices you plan on 

running at the same time. 

2.

 

Total the running watts of these items. 

This is the amount of power you need to 

keep your items running. 

3.

 

Identify the highest starting wattage of 

all devices identified in step 1. Add this 

number to the number calculated in step 

2. Surge wattage is the extra burst of 

power needed to start some electric 

driven equipment. Following the steps 

listed under “Power Management” will 

guarantee that only one device will be 

starting at a time. 

Power Management 

Use the following formula to convert voltage 

and amperage to watts: 

 

Volts x Amps = Watts 

 

To prolong the life of your generator and 

attached devices, follow these steps to add 

electrical load: 

1.

 

Start the generator with no electrical 

load attached. 

2.

 

Allow the engine to run for several 

minutes to stabilize. 

3.

 

Plug in and turn on the first item. It is 

best to attach the item with the largest 

load first. 

4.

 

Allow the engine to stabilize. 

5.

 

Plug in and turn on the next item. 

6.

 

Allow the engine to stabilize. 

7.

 

Repeat steps 5-6 for each additional 

item. 

  NOTE 

Never exceed the generator capacity when 
adding loads.  
 

Summary of Contents for 41331

Page 1: ...Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 7000 Peak Watts 6000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual Owne...

Page 2: ......

Page 3: ...ence Chart 1 2SHUDWLRQ DW LJK OWLWXGH 3 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 14 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintena...

Page 4: ......

Page 5: ...pment Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please...

Page 6: ...n imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or s...

Page 7: ...rotating parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator pro...

Page 8: ...hutoff valve is in the off position and the fuel tank is empty Disconnect the spark plug wire When storing the generator Store away from sparks open flames pilot lights heat and other sources of ignit...

Page 9: ...apacity fuel tank 2 Fuel Valve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris fro...

Page 10: ...120 240 V 30 A Twist Lock protected by a 30 A push to reset circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC 60 Hz single phase loads requiring up to 25 A or 6...

Page 11: ...eces Vibration Mounts 2 pieces Handle Assembly 1 Set Support Leg 1 piece Handle Locking pins 2 pieces Bolt Kit Flat Washers 2 pieces Cap Screws and Nuts 10 sets Axle bushing 2 pieces Washers 4 pieces...

Page 12: ...2 Slide the M10x125 wheel bolt through the washer axle bushing and wheel 3 Slide the bolt through the mount point on the frame 4 Fasten securely with the M10 nut 5 Repeat steps 2 4 to attach the seco...

Page 13: ...ommended type and amount of oil Damage to the generator as a result of failure to follow these instructions will void your warranty 1 Place the generator on a flat level surface 2 Remove oil fill cap...

Page 14: ...ling the fuel tank Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock WARNING Failure to properly ground the generator can result in electric s...

Page 15: ...e equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Starting the Engine 1 Make certain the generat...

Page 16: ...ad for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the ignition switch to the Off position 4 Turn the fuel valve to the Off position Do Not Overload Generator...

Page 17: ...um altitude can damage the engine For operation at lower elevations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emi...

Page 18: ...cap dipstick to add oil 5 Add 1 16 qt 1 1 L of oil and replace oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Spark Plugs 1 Remove the spark plug cable from the...

Page 19: ...Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hours Change oil Every 50 ho...

Page 20: ...rom the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the...

Page 21: ...lons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a 3 4 19 mm long reach plug Use the spark pl...

Page 22: ...Specifications 18 Rev 41331 20110330 English Parts Diagram...

Page 23: ...52030 CPE AVR 1 22 ST02FD 02100008 Brush Support Plate 1 23 ST05FD 1152035 Brush Assembly 1 24 ST05FD 1152002 End Cover 1 25 ST05FD 1152004 5 Flange Bolt M6 179 4 26 ST05FD 1152003 5 Stator Cover 1 27...

Page 24: ...sher 8 2 76 GB6175 M8 Nut M8 2 77 GB5789 M6 12 Flange Bolt M6 12 2 78 ST168FD 1100003 CARB SAI Valve Washer 1 79 ST168FD 1100300 CARB SAI Valve 1 80 ST188FD 1100002 CARB Muffler 1 81 ST188FD 1100103 M...

Page 25: ...ank Wing 2 110 ST188FD 1744002 T Wheel 2 111 ST36QXG 03000002 Bushing 10 5 69 5 2 112 GB96 10 Washer 10 2 113 GB5782 M10 125 Bolt M10 125 2 114 ST02FD 1152010 5 Grounding Wire 1 115 GB97 1 6 Washer 6...

Page 26: ...Specifications 22 Rev 41331 20110330 English Wiring Diagram...

Page 27: ...overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly conne...

Page 28: ...n Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits...

Page 29: ...S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your e...

Page 30: ...s scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior...

Page 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Reviews: