201047 - 2400W DUAL FUEL INvERTER GENERATOR
OPERATION
23
Eco (Economy) Mode
The Eco Mode
button can be activated to turn on economy control
in order to minimize fuel consumption and noise while operating
the unit during times of reduced electrical output. Eco Mode
allows the engine speed to idle during periods of non-use.
The engine speed returns to normal when an electrical load is
connected. When the economy switch is off, the engine runs at
normal speed continuously.
CAUTION
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
Parallel Operation
The Champion model 201047 is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion parallel kit (optional
equipment) is required for parallel operation. Model 100319 is the
recommended model for this unit. For a list of compatible models
or to order a parallel kit, please call customer service at 1-877-
338-0999 or visit
www.championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator’s
manual.
Stopping the Engine
Gasoline
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the fuel vent lever to the “OFF” position.
4. Turn the EZ Start dial to the “STOP” position.
Important:
Always ensure that the dial and fuel vent on the fuel
cap are in the “OFF” position when the generator is not in use.
Propane
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Close the fuel valve on the propane cylinder.