200967 - 3500W DUAL FUEL PORTABLE GENERATOR
ASSEMBLY
17
4. Check engine oil level at every use and add as needed.
MAX
OIL DIP STICK
NOTICE
Once oil has been added, a visual check should show oil about
1-2 threads from running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in
the dipstick while checking.
NOTICE
Check oil level often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.
NOTICE
The first 5 hours of run time are the break-in period for the
unit. During the break in period stay at or below 50% of the
running watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the load will also
cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in
period. Using synthetic oil does not decrease the recommended
oil change interval. Full synthetic 5W-30 oil will aid in starting
in cold ambient < 41º F (5º C) temperatures.
Add Fuel: Gasoline
Use clean, fresh, regular unleaded gasoline with a minimum
octane rating of 87 and an ethanol content of 10% or less by
volume.
y b c
DO NOT mix oil with gasoline.
1. Remove the gasoline cap.
2. Slowly add gasoline to the tank. Tank is full when gasoline
reaches red circle on screen. DO NOT OVERFILL. Gasoline can
expand after filling. A minimum of ¼ in. (6.4 mm) of space left
in the tank is required for gasoline expansion, although more
than ¼ in. (6.4 mm) is recommended. Gasoline can be forced
out of the tank as a result of expansion if overfilled, and can
affect the stable running condition of the generator.
3. The approximate fuel level is shown on the fuel gauge on top
of the fuel tank.
Empty
Full
4. Screw on the gasoline cap and wipe away any spilled fuel.