INSTALLATION STEP 7

Install the Light

•  

Press the release tabs on both sides of lens. 
Gently rotate lens back and downward until the 
lens hinge is in the fully open position. Do not 
remove the lens.

•  

Install up to a 100 watt maximum light bulb in the 
socket. Light bulb size should be A19, standard 
neck only. The light will turn ON and remain lit for 
approximately 4-1/2 minutes when power is 
connected. Then the light will turn OFF.

•  

Reverse the procedure to close the lens.

•  

 Use A19, standard neck garage door opener bulbs 
for replacement.

NOTE: 

Use only a standard light bulb. The use of a 

short neck or speciality light bulb may overheat the 
endpanel or light socket.

INSTALLATION STEP 8

Attach the Emergency Release 
Rope and Handle

•  

Thread one end of the rope through the hole in the 
top of the red handle so “NOTICE” reads right side 
up as shown. Secure with an overhand knot at 
least 1" (2.5 cm) from the end of the rope to 
prevent slipping.

•  

Thread the other end of the rope through the hole 
in the release arm of the outer trolley.

•  

Adjust rope length so the handle is 6 feet (1.83 m) 
above the floor. Ensure that the rope and handle 
clear the tops of all vehicles to avoid 
entanglement. Secure with an overhand knot.

NOTE: 

If it is necessary to cut the rope, heat seal the 

cut end with a match or lighter to prevent unraveling.

To prevent possible SERIOUS INJURY or DEATH from a 
falling garage door:
•  If possible, use emergency release handle to disengage 

trolley ONLY when garage door is CLOSED. Weak or 
broken springs or unbalanced door could result in an 
open door falling rapidly and/or unexpectedly.

•  NEVER use emergency release handle unless garage 

doorway is clear of persons and obstructions.

•  NEVER use handle to pull door open or closed. If rope 

knot becomes untied, you could fall.

Lens Hinge

100 Watt (Max)

Standard Light Bulb

Release Tab

Trolley
Release arm

NOTICE

Emergency
Release Handle

Overhand
Knot

Trolley

To prevent possible OVERHEATING of the endpanel or 
light socket:
•   DO NOT use short neck or specialty light bulbs.
•   DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
•   DO NOT use bulbs larger than 100W.
•  ONLY use A19 size bulbs.

Summary of Contents for Security+ PD300DM

Page 1: ...er s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connect...

Page 2: ...all the trolley 8 Fasten the rail to the motor unit and install the idler pulley 9 Install the chain cable 10 Tighten the chain 11 Installation 11 26 Installation safety instructions 11 Determine the...

Page 3: ...Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding...

Page 4: ...ng in your garage If so a support bracket and additional fastening hardware may be required Installation Step 10 Depending upon garage construction extension brackets or wood blocks may be needed to i...

Page 5: ...ED CEILING Support bracket fastening hardware is required See page 16 Safety Reversing Sensor Header Wall Gap between floor and bottom of door must not exceed 1 4 6 mm Wall mounted Door Control Rail M...

Page 6: ...er Bracket Idler Pulley U Bracket Trolley Chain Spreader Rail Center Back Sections Rail Front header Section Lighted Door Control Button SECURITY Keyless Entry The Protector System Your garage door op...

Page 7: ...8 1 Trolley Threaded Shaft 1 Lock Washer 3 8 1 Lock Nut 1 4 20 2 Bolt 1 4 20x1 3 4 2 Drywall Anchors 2 Clevis Pin 5 16 x1 1 Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Clevis Pin 5 16 x1 1 2 1 Self T...

Page 8: ...about 4 3 4 12 cm from the far end 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 12 NOTE To prevent INJURY while unpacking...

Page 9: ...cm of cable through the window Allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operation Place the...

Page 10: ...cap and onto pin notches until both pins are securely locked in place 3 With the trolley against the screwdriver dispense the remainder of the cable chain along the rail toward the motor unit into the...

Page 11: ...N INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener only on properly b...

Page 12: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possib...

Page 13: ...nting toward the ceiling Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Lag Screw 5 16 9x1 5 8 HARDWAR...

Page 14: ...you may re use the old header bracket with the two plastic spacers included in the hardware bag Place the spacers inside the bracket on each side of the rail as illustrated Position the opener on the...

Page 15: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Page 16: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to o...

Page 17: ...the Lighted Door Control Button securely with 6ABx1 1 2 screws If installing into drywall drill 5 32 holes and use the anchors provided 3 Run bell wire up wall and across ceiling to motor unit Use in...

Page 18: ...he hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement S...

Page 19: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Page 20: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Page 21: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 22: ...is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sender s beam Whe...

Page 23: ...rectly below any structural support across the top of the door 3 Mark drill holes and install as follows depending on your door s construction Metal or light weight doors using a vertical angle iron b...

Page 24: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 25: ...are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that l...

Page 26: ...5 16 18 Lock Washers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully clos...

Page 27: ...e as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won...

Page 28: ...ntrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount r...

Page 29: ...nd run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test...

Page 30: ...s restored after interruption when the opener is activated Light will also turn on when someone walks through the open garage door They will turn off automatically after 4 1 2 minutes Bulb size is A19...

Page 31: ...prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced d...

Page 32: ...interference that may cause undesired operation To prevent possible SERIOUS INJURY or DEATH NEVER allow small children near batteries If battery is swallowed immediately notify doctor To reduce risk...

Page 33: ...The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits De...

Page 34: ...together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If...

Page 35: ...u wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Hand he...

Page 36: ...es and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN th...

Page 37: ...0 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 Door bracket w clevis p...

Page 38: ...108D79 Lens 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41D3058 Universal replacement motor bracket assembly Complete with Motor worm bracket bearing ass...

Page 39: ...when it detects a person entering the garage Sensor can be easily deactivated when desired 3 Button Mini Remote Control with SECURITY With key ring and fastening strip 956D 940D 10 Foot 3 m Rail Exte...

Page 40: ...are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or rep...