background image

12

TRAVEL SPEED: Automatically selected:

There are two travel speeds available for this opener.
The speed is a function of door travel distance and is automatically set during the door travel limit setting process.
* Travel distance longer then 2 metres = REGULAR speed
* Travel distance shorter than 2 metres = SLOW speed

TRAVEL SPEED: Manually selected:

The speed can be set manually if required, once the travel limits have been set, using the following method.

To activate the alternate speed:

PRESS and HOLD both the

UP

and

DOWN

arrows for 3 seconds.The courtesy lamp will flash once to confirm SLOW

speed and twice to confirm REGULAR speed.

PROGRAM THE TRAVEL SPEED (OPTIONAL)

21

TEST THE SAFETY REVERSE SYSTEM

Procedure:

With door opened place a 40 mm obstacle (1)

laid flat on the floor under the garage door. Operate the

door in the down direction. The door must reverse off the

obstacle. If the door stops on the obstacle, remove obstacle

and repeat Program the Limits and Force Steps, then

repeat safety reverse test.

When the door reverses off the 40 mm obstacle, remove

the obstacle and run the opener through a complete travel

cycle. Door must not reverse in closed position. If it does,

repeat Program the Limits and Force then repeat safety

reverse test.

1

40mm

The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle

laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing

garage door. Repeat test once a month and adjust as needed.

20

Low Standby Mode (sub 1 watt) is activated by the factory to deliver the lowest possible standby power.
In this mode the External Accessories Power and the IR Beams are turned OFF when the door is closed and the courtesy light
is OFF.
At mains turn ON: Courtesy light flashes 2 times = Low Standby Mode

Courtesy light flashes 10 times = Normal Standby Mode

The Normal Standby Mode will need to be activated for External Accessories Power.

To Activate Normal Standby Mode:

Turn the mains power OFF.
PRESS and HOLD both the

UP

and

DOWN

arrows simultaneously.

Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 10 flashes.
Release the arrow buttons.

To Activate Low Standby Mode:

Turn the mains power OFF.
PRESS and HOLD both the

UP

and

DOWN

arrows simultaneously.

Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 1 flash.
Release the arrow buttons.

PROGRAM THE LOW STANDBY MODE (OPTIONAL)

22

Summary of Contents for PowerLife Plus CS100EVO

Page 1: ...eference CS100EVO Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY www chamberlaindiy com au www chamberlaindiy co nz ...

Page 2: ...space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer SAVE THESE INSTRUCTIONS Failure to comply with the following instructions may result in serious personal injury or property damage Read and follow all instructions carefully The garage door opener is designed an...

Page 3: ...tirely by its springs Raise and lower the door to see if there is any binding or sticking 20 kgf is the absolute maximum allowable force to raise or lower the door in any position If your door binds sticks or is out of balance call a trained door technician DOOR TYPES Sectional Door with curved track MAX door height 2 2 m PowerLift Plus CS100EVO To suit spring balanced Sectional doors up to 16 0 m...

Page 4: ... w w w chamberlaindiy com au ww w chamberlaindiy co nz CARTON INVENTORY 1 Opener 2 Hand held transmitter x 2 3 Remote control visor mount 4 Curved door arm 5 Hanging bracket 2 6 Rail bracket 7 Header bracket 8 Door bracket 9 Hardware bag 10 Rail assembly 11 C Rail bracket 2 12 Centre Rail Bracket 13 Manual 14 Warning labels 15 Warranty card Your garage door opener and rail are packed in a single c...

Page 5: ...re rail bracket As you proceed with the assembly installation and adjustment procedures in this manual you may find it helpful to refer back to this illustration of a completed installation COMPLETED INSTALLATION 10 4x 9 8x 8 4x 7 1x 6 1x 1 1x 2 1x 3 4x 4 4x 5 4x HARDWARE PROVIDED 1 Clevis pin 80 mm 2 R clip 3 Hexagonal head screw 4 Nut M8 5 Flat washer M8 6 Clevis Pin 7 R clip 8 Screw ST6 x 50 mm...

Page 6: ...rols and learn the forces manually 7 Indicator LED used to indicate various programming modes No Function Colour Polarity Comment 0 E Serial port Green ve Serial Communication Input 1 Push button Red ve Dry Contact input for push button wired wall controls 2 Ground White ve Common terminal for push button 2 Ground White ve Common terminal for IR Beams 3 IR Sensor Gray ve Merlin IR Beam Input pulsi...

Page 7: ...ews 5 This completes the assembly of the door opener to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 4 parts The carriage push rod release handle the guide pulley and the lintel bracket with belt tensioner are in the front part A The seating for the drive shaft and the sprocket are in the rear part B Hardware items are placed in the rails during tr...

Page 8: ...er Bracket Position the assembled opener on the garage floor below the header bracket Use foam packing material as a protective base NOTE If the door spring is in the way youʼll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and secure with the 80 mm clevis pin...

Page 9: ...between door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively parallel to the horizontal door panels 14 Disengage the trolley mechanism see section Operating the manual release and slide it back towards the powerhead Secure the hanging push arm up into the rail as...

Page 10: ... a sound structural support above the opener 1 Postion the opener as in the previous step Check the rail is centred over the door Ensure the rail brackets fig 1 is on the Powerhead end of the rail in a position as close to the opener as possible X 2 If mounting directly onto the ceiling fig 2 screw the bracket directly into a structural support on the ceiling 3 If hanging the opener below the ceil...

Page 11: ...bly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL RELEASE The manual release mechanism enables the door to be manually operated during power outages or in an emergency The RED Manual Release cord is preassembled to the trolley When the opener is installed the handle should be no higher then 1 8 metres from the floor The cor...

Page 12: ...rrow Button will begin to flash figure 4 4 Press and hold the DOWN Arrow Button until the door is in the desired DOWN position figure 5 NOTE The UP and DOWN Arrow Buttons can be used to move the door up and down as needed 5 Once the door is in the desired DOWN position press and release the PROG Button The UP Arrow Button will begin to flash figure 2 SETTING THE FORCE AUTO 6 Press and release the ...

Page 13: ...it does repeat Program the Limits and Force then repeat safety reverse test 1 40mm The safety reverse system test is important Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor Failure to properly adjust opener may result in serious personal injury from a closing garage door Repeat test once a month and adjust as needed 20 Low Standby Mode sub 1 watt is activated by ...

Page 14: ...e bolts as shown Adjust right and left side bracket assemblies to the same distance out from mounting surface Make sure all door hardware obstructions are cleared Tighten the lock nuts Centre each sensor unit in a C wrap with lenses pointing toward each other across the door Secure sensors with the hardware provided Finger tighten the wing nut on the receiving eye to allow for final adjustment Sec...

Page 15: ...the courtesy light flashes twice 3 Press the UP button once for each 10 second increment required of TTC figure 2 eg twice for 20 seconds Press the DOWN arrow to reduce if needed 4 Press and release the PROG button to save this time figure 3 Courtesy light will flash once TTC is now activated TEST Operate the door to the UP position Keep clear of the IR Beams and check the door closes after the pr...

Page 16: ...gether for 3 seconds figure 1 The Courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all remote control codes as in the Wireless programming section will also delete this feature PARTIAL OPENING FEATURE PET 15 Indicator LED Indicator LED figure 1 figure 2 Indicator LED figure 3 or figure 4 26 1 service www chamber a n de nfo chamber a n de B B A 2 114A3361 For Se...

Page 17: ...you release the remote control push button before the opener light flashes the opener has not learned the code Now the opener will operate the door when the remote control push button is pressed To Erase all Remote Control Codes 1 Press and Hold the yellow LEARN button on the opener until the indicator LED goes ON and continue holding for approx 6 seconds until the indicator LED goes out 1 Release...

Page 18: ...Once a Month Manually operate door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjustments Once a Year Lightly grease the belt and inside the rail assembly where the trolley slides Be careful to use gloves around any sharp metal edge of the rail Int...

Page 19: ...E1702M 770AML E940C 4 5 1 2 E950C 1 Model E950C 2 Channel remote control 2 Model E940C 1 Channel visor remote control 3 Model 770AML The Protector SystemTM 4 Model E1702M Quick release lock 5 Model 760AML Outside keyswitch 31 ...

Page 20: ...acturing process and may have dislodged 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic code on next page 1 Opener doesn t operate from either door control or remote Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are controlled by a wall switch Have you disengaged all ...

Page 21: ...d Realign both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internally the possible cause may be the motor logic board or RPM sensor Try resetting door travel limits Contact service centre R...

Page 22: ...d 150 mm per second LED light 25 Watt equivalent Door Linkage Adjustable door arm Pull cord trolley release Safety Personal Push button stop in UP and DOWN direction Automatic safety reverse in both UP and DOWN direction Electronic Automatic force adjustment Electrical Transformer overload protector and low voltage push button wiring Limit Device Mechanical Passpoint RPM sensor Limit Adjustment El...

Page 23: ... and or return the Unit to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding specifications installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than a Professional Dealer to repair dismantle reinstall or move the Unit t...

Page 24: ...ademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc Warranty Registration To validate your warranty you must complete the registration form online at chamberlaindiy com au warranty or chamberlaindiy co nz warranty ...

Reviews: