Operation Of Your Opener

Your opener can be activated by any of the following devices:

• The Remote Control Transmitter. Hold the push button down until the door starts to move.

• The Backlit Door Control Button (if you have installed this accessory). Hold the button down until door starts to move.

• The Outside Keylock or Keyless Entry System (if you have installed either of these accessories).

Opening the Door Manually:

Door should be fully closed if possible. Weak or broken springs could allow an open door to fall rapidly.

Property

damage or serious personal injury could result.

The door can be opened manually by pulling the release handle down. To reconnect the door, activate the unit.

Do not use the manual release handle to pull the door open

or closed.

When the Opener is Activated by Remote Control or Door Control Button:

1. If fully open, the door will close.

2. If closed, the door will open.

3. If opening or closing, the door will stop.

4. If partially open, the door will move in the opposite direction of last travel.

5. If an obstruction is encountered while closing, the door will reverse to the open position.

6. If an obstruction is encountered while opening, the door will reverse for 1 second.

7. The optional Protector System™ uses an invisible beam which, when broken by an obstruction, causes a closing

door to open and prevents an open door from closing. It is STRONGLY RECOMMENDED for homeowners with

young children.

Allow a 15 minute cooling period after 5 continuous operations of the opener.

The opener light will turn on: 1. when opener is initially plugged in;

2. when the power is interrupted; 3. when the opener is activated.

The light turns off automatically after 2-1/2 minutes. Bulb size is

21 Watts maximum.

41A5674-2

Replacement Parts

(1)

41A5644

Trolley with Chain/Cable Assy.

(2)

41A5674-2

Head Only

(3)

41A5643

Hardware Bag

(4)

012B0905

Door Bracket

012B0906

Door bracket

(5)

012C0788

Header Bracket

(6)

012C0908

Rail end piece

(7)

41A5675

Rail Hardware

(8)

41A5676

Rail Sections

Summary of Contents for MotorLift ML500

Page 1: ...TM TM Illustrated Instruction Manual for ML500 Garage Door Operator Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 www motorlift com au Chamberlain New Zealand Ltd P O Box 100 221 Auckla...

Page 2: ...2...

Page 3: ...r installation reinforcement kit The safety reverse system test is very important Your garage door MUST reverse on contact with a 40mm obstacle placed on the floor Failure to properly adjust the opene...

Page 4: ...red 1 A B Door Types A One Piece Door with Horizontal Track Only B Sectional Door with Curved Track NOTE Unit will not work with One Piece Doors with Horizontal and Vertical Tracks Double Wing Doors o...

Page 5: ...1 1 4 4 1 5 5 4 6 2 2 4 5 4 3 3 5 Assemble Rail Place Rail pieces 1 on a flat surface for assembly Take special note of the raised line on the Rail pieces 4 these lines MUST line up in order for the...

Page 6: ...be installed in the position shown 1 2 3 2 4 7 1 2 1 3 4 4 8 6 Insert Chain Cable into Rail Slide Cable Pulley Bracket 1 into Rail assembly 3 be sure to insert Cable Pulley Bracket as shown Push Cabl...

Page 7: ...pener be installed 2 1m 7 feet or more above the floor where space permits Attach Rail to Unit Turn Rail assembly over Wrap Chain around Drive Sprocket 1 Slide Rail assembly 2 toward unit and into slo...

Page 8: ...ward the opener Mark all of the header bracket holes 5 Drill 4 5 mm 3 16 pilot holes and fasten the header bracket with wood screws 3 For concrete ceiling mount use concrete anchors 6 provided Clearan...

Page 9: ...et Bolts Mark length on ceiling starting at the Header Wall along this point is where the unit will be mounted Lift door to full open position rest opener on door Insert Square Head Screws A into Rail...

Page 10: ...he unit will not function properly Close garage door by hand Determine the position of the Close Limit Switch 1 Long wire by aligning the center of trolley and the center of the Limit Switch The Limit...

Page 11: ...nds All previous codes are now erased Reprogram each Remote or Keyless Entry you wish to use Setting the Force The Force is programmed to operate most doors however if Limits are not able to be set or...

Page 12: ...oor Control optional Insert a small flat head screwdriver into the top of the Wall Control 10 gently pry the cover off Fasten to an inside garage wall with sheet metal screws 8 as follows Install bott...

Page 13: ...en the door will close 2 If closed the door will open 3 If opening or closing the door will stop 4 If partially open the door will move in the opposite direction of last travel 5 If an obstruction is...

Page 14: ...rce Clear any ice or snow from garage floor area where garage door closes If door reverses in fully closed position adjust the Close Limit Repeat safety reverse test after adjustment is complete The n...

Page 15: ...ect abuse wear and tear accident electrical storm excessive use or conditions other than normal domestic use This warranty does not cover any problems with or relating to the garage door or garage doo...

Page 16: ...114A3449 ANZ NOTES...

Reviews: