en 12/13
DIAGNOSTIC CODE
Up Arrow Down Arrow
Flash(es)
Flash(es)
5
1
5
5
6
1
SYMPTOM
Terminal 1+2 for wall control is short-
ened longer than 4 seconds
Low voltage
Maximum radio memory has been
reached.
SOLUTION
Check wiring for push button if button is stuck and activated permanently. Remove
wiring from terminal 1+2 on operator as test. Do not run push button wires next to high
voltage wiring or in same conduit.
The operator has been shut off due to lower voltage supplied than allowed.
If an external backup battery pack is installed, check if empty. If mains supply is used,
check wiring and supply.
Maximum capacity for storage of remote controls has been reached. The first remote
control or more previously programmed remote controls’ codes have been replaced by
a new one. To reset diagnostic remove power from the operator.
Optional Accessories
1. TX4RUNI -
4-channel remote control
2. 128REV -
Wireless Wall Control 2-Channel
3. 747REV -
Keypad
4. 830REV -
myQ Starter Kit (G Photocells)
5. 829REV -
Garage Door Monitor
6. 1REV -
Quick release
7. 1702REV -
Quick release
8. 75REV -
Wired push button
9. FLA-1LED -
Flashing light
10. 771REV -
Photocells
11. 41REV -
Key switch (surface mount)
12. 16200LM -
Door in Door contact
34
Summary of Contents for ML1000EV
Page 227: ...rus 01 13 1 2 50 1 8...
Page 230: ...rus 04 13 B 1 3 4 5 4 5 1 1 0 100 2 100 130 15 16 1 2 1 8 17 1 5 6 3 5 6 5 19 18...
Page 231: ...rus 05 13 20 22 21 190 www chamberlain eu 23 24 1 2 3 4 5 6 1 33 7 50 1 50 50 20 24...
Page 233: ...K 2 3 2013 E F 747REV 4 G 747REV H 747REV I myQ 830REV Gateway J 829REV rus 07 13...
Page 234: ...1 2 LIGHT 2 5 1 2 3 2 5 28 rus 08 13 30 30 1 28 29 27...
Page 235: ...XXXXX 31 2002 96 EG 32 rus 09 13 1 2 3 4 33 30 2...
Page 236: ...rus 10 13 5 6 7 2 5 8 2 5 9 10 11 12 13 14 15 16 17 1 2...
Page 237: ...rus 11 13 1 1 1 2 1 3 1 4 1 5 1 6 2 1 5 3 2 4 1 4 4 5 4 6 15 15...
Page 282: ......
Page 283: ......