WIRING

FINE TUNE THE FORCE

PROGRAMMING

INITIAL LIMITS AND FORCE ADJUSTMENT

OBSTRUCTION TEST

When limits are set properly the operator will automatically exit limit setting mode.

5

1

  

Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode.

2

   Press and hold one of the MOVE GATE buttons to move the gate to the 

open or close limit.

3

   Press and release the SET CLOSE or SET OPEN button 

depending on which limit is being set.

4

   Press and hold one of the MOVE GATE button to move the 

gate to the other limit.

5

   Press and release the SET CLOSE or SET OPEN button depending on which 

limit is being set.

6

1

  Open and close the gate with the test buttons. 

2

   If the gate stops or reverses before reaching the fully open or 

closed position, increase the force by turning the force control 

slightly clockwise. 

7

8

1

  

Press and release the LEARN 

button (operator will beep 

and green XMITTER LED will 

light).

2

   Press the remote control button for the 

desired function. The 

operator will automatically 

exit learn mode (operator 

will beep and green 

XMITTER LED will go out) 

if programming is 

successful.

6

  Cycle the gate open and close. This automatically sets the force.

The FORCE DIAL on the control board is used for fine tuning the force. The force setting should be high enough that 

the gate will not reverse by itself nor cause nuisance interruptions, but low enough to prevent serious injury to a 

person. The force setting is the same for both the open and close gate directions.

3

   Perform the “Obstruction Test” after every force setting adjustment (see below).

1

   Open and close the gate with the test buttons, ensuring that the gate is stopping at the proper open and close limit 

positions.

2

   Place a solid object between the open gate and a rigid structure. Ensure that the gate, the solid object, and the rigid 

structure can withstand the forces generated during this obstruction test.

3

   Run the gate in the close direction. The gate should stop and reverse upon contact with the solid object. If the gate 

does not reverse off the solid object, reduce the force setting by turning the force control slightly counter-clockwise. 

The gate should have enough force to reach both the open and close limits, but MUST reverse after contact with a 

solid object.

4

  Repeat the test for the open direction.

To protect against fire and electrocution:

•  DISCONNECT power and battery BEFORE 

installing or servicing operator.

For continued protection against fire:

•  Replace ONLY with fuse of same type and 

rating.

WIRE THE ENTRAPMENT PROTECTION DEVICES

Connect the entrapment protection device to the EYES EDGE terminal on the control 

board.
•   Close Photoelectric Sensor Entrapment Protection: Connect wires from the 

photoelectric sensors to the Inputs on the CLOSE EYES/INTERRUPT terminal.

•   Close Edge Entrapment Protection: Connect wires from the entrapment protection 

device to the Inputs on the CLOSE EDGE terminal.

•   Open Entrapment Protection: Connect wires from the entrapment protection device 

to the Inputs on the OPEN EYES/EDGE terminal.

POWER WIRING

This operator can be wired for either 120 Vac or 240 Vac or a 

solar panel (not provided). These instructions show a 120 Vac 

application. For information regarding a 240 Vac or solar 

application refer to the installation manual.

1

2

EARTH GROUND ROD

1

  

Install the earth ground rod within 3 feet 

of the operator.

2

  

Run wire from the earth ground rod to the 

operator.

Check national and local 

codes for proper depth

4

CONNECT BATTERIES

Red Wire 

Black Wire 

Jumper

1

   Connect the battery wires to the 

J15 plug on the control board.

2

   Turn ON AC power to the 

operator.

3

   Turn ON the AC power switch on 

the operator.

1

   Turn off the AC power from the main 

power source circuit breaker.

2

   Run the AC power wires to the 

operator.

3

   Connect the green wire to the earth 

ground rod and AC ground using a 

wire nut. 

NOTE: 

The earth ground 

rod can be grounded to the chassis.

4

   Connect the white wire to NEUTRAL 

using a wire nut.

5

   Connect the black wire to HOT using 

a wire nut.

Junction Box

SET OPEN SET CLOSE

OFF

PRESS &

RELEASE

TO BEGIN

LIMIT

ALARM

RESET

MOVE
GATE

5

INPUT POWER

STATUS:

PRESS &

RELEASE

TO BEGIN

SETUP

LIMIT

TO BEGIN

LIMIT

PRESS &

RELEASE

TO BEGIN

ALARM

RESET

60

180 MIN

MAX

BATT LOW

NETWORK

OPEN

CLOSE

ST
OP

XMITTER

NETWORK

AC Power Switch