Chamberlain LC36M Installation Manual Download Page 4

4

Screw with 

nylon washer

Monitored

Light Curtain

Mounting

Bracket

Monitored

Light Curtain

Monitored

Light Curtain

Nylon Nut

6" (15 cm) maximum above and a

minimum of 3" (7.62 cm) from the floor

6" (15 cm) maximum above and a

minimum of 3" (7.62 cm) from the floor

INSTALL ONE SET OF MONITORED LIGHT CURTAINS AS STANDALONE PRIMARY ENTRAPMENT PROTECTION

The mounting brackets must be securely fastened to a solid surface such as a wall framing. If installing the mounting brackets in masonry construction, add 

a piece of wood at each location to avoid drilling extra holes in the masonry. 

NOTE: 

If the Monitored Light Curtain is installed with coil cord, the coil cord 

needs to be secured so it will not interrupt the light beams.

1.   Fasten the mounting brackets loosely to both Monitored Light Curtain with the screws provided. 
2.   Measure a maximum of 6 inches above the floor. Mark this location.  The lowest optical sensor of the Monitored Light Curtain must be installed at or below 

this point. In this application, in order to assure that the lowest optical sensor is mounted no higher than 6" above the ground, the light curtain wires must 

be oriented at the top of the light curtain in this application.

3.   Hold the Monitored Light Curtain up to the desired mounting location with the cable end pointing upward. Secure the bottom mounting bracket to the 

mounting surface. 

4.   Make sure the Monitored Light Curtain is level and secure the upper mounting bracket to the mounting surface. 
5.   Tighten the screws to secure the Monitored Light Curtain to the mounting bracket. 
6.   Secure the other Monitored Light Curtain to the opposite side of the door following steps 2 - 5, making sure they are aligned.
7.  Run wires to the operator.
8.   Twist like colored wires together, brown to brown and blue to blue. 

To prevent possible product damage and incorrect operation:

•  

NEVER scratch or paint the optical sensors. 

•  

DO NOT drill ANY additional holes into the Monitored Light Curtain.

•   Correctly connect and align the Monitored Light Curtain transmitter 

and receiver.

•  

DO NOT bend or twist the Monitored Light Curtain. 

•   Oil may damage the Monitored Light Curtain cable so contamination 

MUST be avoided at ALL times.

•   DO NOT mount the Monitored Light Curtain where sunlight or other 

external infrared light sources will shine directly into the optical sensors 

of the Monitored Light Curtain receiver. If necessary, switch the 

mounting side of the Monitored Light Curtain transmitter and receiver.

INSTALLATION

T

R

DOOR 1

DOOR 2

DOOR 3

R

 = Receiving Monitored Light Curtain

T

 = Transmitting Monitored Light Curtain 

R

T

T

R

T

R

T

R

Blocking Material

R

 = Receiving Monitored Light Curtain

T

 = Transmitting Monitored Light Curtain 

Screw 

Mounting Bracket

Nut with 

Nylon Insert

In highly-reflective

environments, separation

up to 12" (15cm) may be

required between

Monitored Light Curtains.

6" (15 cm) maximum above and a

minimum of 3" (7.62 cm) from the floor

INSTALL TWO SETS OF MONITORED LIGHT CURTAINS

Installing two sets of Monitored Light Curtains on the same 

door is recommended when taller portions of vehicles and 

equipment must be protected. Applicable with HCT, LOGIC 5.0, 

and HPH1 Operators.
1.   Install the first set of Monitored Light Curtain on the door as 

described in the Install One Set of Monitored Light Curtain 

section.

2.   Install the second set of Monitored Light Curtain above the 

first set. The black and white wires are wired in parallel and 

the blue and brown wires are wired in parallel.

3.   Position the Transmitters and Receivers as shown in the 

image below to prevent cross-talk. In this application, the 

upper Light Curtain may be mounted with wiring oriented up 

or down.

NOTE: 

When a 2nd Monitored Entrapment Protection device 

is used with the HCT Operator, the 2nd device must be wired 

to the existing HCT Expansion Board. When a 2nd Monitored 

Entrapment Protection device is used with a LOGIC 5.0 Operator, 

the 2nd device must be wired using the CPS3CARD (plug-in option 

card.) When a 2nd Monitored Entrapment Protection device is used 

with HPH1, no additional hardware is required.

NOTE: (images not to scale)

NOTE: (images not to scale)

NOTE: 

In this application, in 

order for the lowest optical 

sensor to be no higher 

than 6" above the floor, the 

wiring of the Monitored Light 

Curtain must be facing in the 

upward direction. If installed 

with the wires facing down, 

the lowest optical sensor will 

be much higher than 6" above 

the ground; it will be approx. 

9-10" above the ground.

NOTE: 

In this application, in order for the lowest optical sensor to be no higher than 6" 

above the floor, the wiring of the Monitored Light Curtain must be facing in the upward 

direction. If installed with the wires facing down, the lowest optical sensor will be much 

higher than 6" above the ground; it will be approx. 9-10" above the ground.

Summary of Contents for LC36M

Page 1: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Model LC36M LC36M41 LiftMaster Monitored Light Curtain NOTE Images not to scale ...

Page 2: ...ling doors that is designed with 8 optical sensors that form 22 total invisible light beams These light beams create a cross pattern or netting effect for maximum protection against entrapment When properly connected and aligned the Monitored Light Curtain will detect an obstruction in the path of the light beams If an obstruction breaks any light beam while the door is closing the operator will s...

Page 3: ...is UL Approved and compatible with LiftMaster LOGIC 5 0 Heavy and Standard Duty Medium Duty DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL Fire Door Operators FDC FDCL FDO A FDO B and Egress LGE Commercial Door Operators The Monitored Light Curtain is for indoor use only but may be installed in areas exposed to rain or moisture INTRODUCTION The images in this document are for reference only ...

Page 4: ...ine directly into the optical sensors of the Monitored Light Curtain receiver If necessary switch the mounting side of the Monitored Light Curtain transmitter and receiver INSTALLATION T R DOOR 1 DOOR 2 DOOR 3 R Receiving Monitored Light Curtain T Transmitting Monitored Light Curtain R T T R T R T R Blocking Material R Receiving Monitored Light Curtain T Transmitting Monitored Light Curtain Screw ...

Page 5: ...Set of Monitored Light Curtain section INSTALLATION INSTALL ONE SET OF MONITORED LIGHT CURTAINS ON TOP OF PHOTO SENSOR EYE Monitored Light Curtains may also be used as a 2nd Monitored device in tandem with a photo eye on LOGIC 5 0 and HCT Operators The lowest beam of the Primary monitoring device must be mounted no higher than 6 above the ground The vertical distance between the photo eye and the ...

Page 6: ... CLOSE OPEN TTC 24VAC 24VAC LMEP EDGE OPEN CLOSE MAS COMMON TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Blue Brown Logic Board Logic Board Brown Blue White Black Black White Brown Blue HEAVY AND STANDARD DUTY LOGIC 5 0 manufactured 2014 and later MEDIUM DUTY LOGIC manufactured after 2010 FIRE DOOR MODEL ...

Page 7: ...and reverse TEST THE PHOTOELECTRIC SENSORS IF PRESENT IN THE APPLICATION 1 With the door in the full open position place a solid object in the path of the photoelectric sensors and press the close button The operator should not move 2 Remove the solid object and press the close button The door should close 3 While the door is closing obstruct the photo beam by moving a solid object in the path of ...

Page 8: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Modèles LC36M LC36M41 Rideau de détection lumineux LiftMaster REMARQUE Les images ne sont pas à l échelle ...

Page 9: ...elles et roulantes Il est conçu avec 8 capteurs optiques qui forment 22 faisceaux lumineux invisibles qui forment au total 22 faisceaux lumineux invisibles Ces faisceaux lumineux créent un motif croisé ou un effet de filet pour une protection maximale contre le coincement Lorsqu il est correctement connecté et aligné le rideau de détection lumineux détecte toute obstruction dans la trajectoire des...

Page 10: ...UL et compatible avec LiftMaster LOGIC 5 0 standard moyen et lourd DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL opérateurs de porte coupe feu FDC FDCL FDO A FDO B et opérateurs de porte commerciale d évacuation LGE La rideau de détection lumineux est conçu à un usage intérieur uniquement mais peut être installé dans des zones exposées à la pluie ou à l humidité INTRODUCTION Les images de c...

Page 11: ...eux Si nécessaire inversez le côté de montage de l émetteur et du récepteur du rideau de détection lumineux INSTALLATION R E E R E R PORTE N 1 PORTE N 2 PORTE N 3 E R E R Matériel de blocage Vis Support de fixation Écrou avec guide en nylon R Rideau de lumière surveillé récepteur E Rideau de lumière surveillé émetteur Dans les environnements hautement réfléchissants une séparation allant jusqu à 3...

Page 12: ...UE CAPTEUR DE LUMIÈRE Les rideaux de détection lumineux peuvent également être utilisés comme deuxième dispositif surveillé en tandem avec une cellule photoélectrique capteur de lumière sur les opérateurs LOGIC 5 0 et HCT La poutre la plus basse du dispositif de surveillance principal ne doit pas être montée à plus de 6 po du sol La distance verticale entre la cellule photoélectrique et le bas du ...

Page 13: ...C 24VAC LMEP EDGE OPEN CLOSE MAS COMMON TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Bleu Brun Carte mère Carte mère Brun Bleu Blanc Noir Noir Blanc Brun Bleu LOGIC 5 0 STANDARD ET LOURD fabriqués à partir de 2014 LOGIC MOYEN fabriqués après 2010 PORTE COUPE FEU MODÈLE FDO B LJ8900W LJ8950W DDO8900W VFOH ...

Page 14: ...ESTER LES CAPTEURS PHOTOÉLECTRIQUES LE CAS ÉCHÉANT 1 Lorsque la porte est en position d ouverture complète placez un objet solide dans la trajectoire des capteurs photoélectriques et appuyez sur le bouton de fermeture L opérateur ne doit pas bouger 2 Retirez l objet solide et appuyez sur le bouton de fermeture La porte doit se fermer 3 Pendant que la porte se ferme obstruez le faisceau photoélectr...

Page 15: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Modelo LC36M LC36M41 Cortina de luz monitoreada LiftMaster NOTA las imágenes no están a escala ...

Page 16: ...ra el atrapamiento que se utiliza con puertas seccionales y enrollables y está diseñado con 8 sensores ópticos que forman 22 haces de luz invisibles en total Estos haces de luz crean un patrón cruzado o un efecto de red para una máxima protección contra el atrapamiento Cuando se conecta y alinea correctamente la cortina de luz monitoreada detectará una obstrucción que ocurra en el camino de los ha...

Page 17: ...a aprobación UL y es compatible con operadores de puertas LiftMaster de servicio pesado y estándar LOGIC 5 0 de servicio mediano DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL operadores de puertas contraincendios FDC FDCL FDO A FDO B y operadores de puertas comerciales de evacuación LGE La cortina de luz monitoreada es solo para uso en interiores pero puede instalarse en áreas expuestas a l...

Page 18: ... los sensores ópticos del receptor de la cortina de luz monitoreada Si es necesario cambie el lado de montaje del transmisor y receptor de la cortina de luz monitoreada INSTALACIÓN R T T R T R PUERTA 1 PUERTA 2 PUERTA 3 T R T R Material de bloqueo Tornillo Ménsula de montaje Tuerca con inserto de nylon R Cortina monitoreada de rayos infrarrojos receptora T Cortina monitoreada de rayos infrarrojos ...

Page 19: ...O DE CORTINAS DE LUZ MONITOREADA EN LA PARTE SUPERIOR DEL OJO DEL FOTOSENSOR Las cortinas de luz monitoreada también se pueden usar como un segundo dispositivo monitoreado junto con una fotocélula en los operadores LOGIC 5 0 y HCT El haz de luz más bajo del dispositivo de monitoreo primario debe montarse a no más de 6 sobre el suelo La distancia vertical entre el ojo de la fotocélula y la parte in...

Page 20: ...N TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Azul Marrón Tarjeta lógica Tarjeta lógica Marrón Azul Blanco Negro Negro Blanco Marrón Azul LOGIC 5 0 DE SERVICIO PESADO Y ESTÁNDAR fabricado en 2014 y posterior LOGIC DE SERVICIO MEDIANO fabricado después de 2010 PUERTA CONTRAINCENDIOS MODELO FDO B LJ8900W L...

Page 21: ...ORES FOTOELÉCTRICOS SI ESTÁN PRESENTES EN LA APLICACIÓN 1 Con la puerta en la posición completamente abierta coloque un objeto sólido en el camino de los sensores fotoeléctricos y presione el botón de cierre El operador no debe moverse 2 Quite el objeto sólido y presione el botón de cierre La puerta debe cerrarse 3 Mientras la puerta se cierra obstruya el haz de fotocélulas moviendo un objeto sóli...

Page 22: ... 2021 LiftMaster All Rights Reserved Tous droits réservés Todos los derechos reservados 114 5541C ...

Reviews: