INVENTARIO EN LA CAJA

ESPECIFICACIONES

Ópticas

Rango de funcionamiento: ................................. 3 - 33 pies (0.91 - 10 metros)
Área de cobertura: zona de detección de .................................... 36" (91.4 cm)
Número de sensores ópticos: .......................................................................... 8
Número de haces de luz invisibles: ............................................................... 22
LED del receptor: ......................................................................................Verde
LED del transmisor: .................................................................................Ámbar

Eléctricas

Consumo de corriente .............................................................................40 mA
Voltaje de suministro: .................................................. 18 a 30 voltios CA o CC
Tipo de salida: ............................................................ colector abierto, pulsado

Mecánicas

Material de la carcasa: ....................................................... Aluminio anodizado
Longitud del cable LC36M: ............................................................... 6' 6" (2 m) 
Longitud del cable LC36M41: ........................................................41' (12.5 m)
Clasificación de la carcasa: ........................................................................IP 67
Rango de temperatura de funcionamiento: ..- 40 °F a + 140 °F (- 40 °C a + 60 °C)
Rango de temperatura de almacenamiento: .... - 40 °F a + 185 °F (- 40 °C a + 85 °C)

Dimensiones

Receptor de la cortina

de rayos infrarrojos

Ménsulas de montaje (4)

Transmisor de la cortina

de rayos infrarrojos

Extremo del cable rojo

LED verde

Extremo del

cable negro

LED ámbar

Sensores ópticos (8)

Material de bloqueo

86.1 cm

(2 pies 9.5 pulg.)

.5 mm (2 pulg.)

.7 mm (0.27 pulg.)

DEL

112 cm

(3 pies 8.25 pulg.)

46.3 cm

(1 pie 6.23 pulg.)

.12 mm (47 pulg.)

111.8 cm (44 pulg.) de longitud con zona de detección de 91.4 cm (36 pulg.)

Ménsulas de montaje extendidas de 25.4 cm (10 pulg.) con refuerzo para puertas

con un borde de 5.08 cm (2 pulg.)

25.4 cm (10 pulg.)

5.08 cm (2 pulg.)

2.54 cm (1 pulg.)

APLICACIÓN

La cortina de luz monitoreada tiene la aprobación UL y es compatible con 

operadores de puertas LiftMaster de servicio pesado y estándar LOGIC 

5.0, de servicio mediano, DDO8900W, LJ8900W, LJ8950W, ATSW, VFOH, 

HPH1, HPH2, HCTDCUL, operadores de puertas contraincendios (FDC, 

FDCL, FDO-A , FDO-B) y operadores de puertas comerciales de evacuación 

(LGE). La cortina de luz monitoreada es solo para uso en interiores, pero 

puede instalarse en áreas expuestas a la lluvia o la humedad.

INTRODUCCIÓN

Las imágenes utilizadas en este manual son solo como referencia y su producto puede verse diferente.

ACCESORIOS

Kit de conductos

 ...................................................................... OES-COND

Kit de conductos con 2 cajas de conexiones y 2 cables flexibles.

Fuente de alimentación con enchufe

 ......................................100 MAPS 

Para operadores de puertas comerciales DDO8900W, LJ8900W, LJ8950W, 

ATSW LiftMaster de servicio mediano que tienen poca o ninguna potencia 

para accesorios disponibles. También para usar con operadores LOGIC 5.0 

para proporcionar energía adicional a las cortinas de luz cuando se usan 

múltiples accesorios.  Siempre se requiere la fuente 100MAPS cuando se 

emplean 2 juegos de cortinas de luz. Se pueden alimentar hasta 2 juegos de 

cortinas de luz con una sola fuente 100MAPS.

Tarjeta opcional con enchufe

 .................................................CPS3CARD

Se requiere para cablear el segundo dispositivo de protección contra 

atrapamiento monitoreado a los operadores LOGIC 5.0.

No se muestra

  Tornillos, arandelas y tuercas con inserto de nailon

  Conectores de cable (6)

  Manual de instalación

  Modelo LC36M - Longitud del cable 6' 6" 

  Modelo LC36M41 - Longitud del cable 41'

Summary of Contents for LC36M

Page 1: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Model LC36M LC36M41 LiftMaster Monitored Light Curtain NOTE Images not to scale ...

Page 2: ...ling doors that is designed with 8 optical sensors that form 22 total invisible light beams These light beams create a cross pattern or netting effect for maximum protection against entrapment When properly connected and aligned the Monitored Light Curtain will detect an obstruction in the path of the light beams If an obstruction breaks any light beam while the door is closing the operator will s...

Page 3: ...is UL Approved and compatible with LiftMaster LOGIC 5 0 Heavy and Standard Duty Medium Duty DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL Fire Door Operators FDC FDCL FDO A FDO B and Egress LGE Commercial Door Operators The Monitored Light Curtain is for indoor use only but may be installed in areas exposed to rain or moisture INTRODUCTION The images in this document are for reference only ...

Page 4: ...ine directly into the optical sensors of the Monitored Light Curtain receiver If necessary switch the mounting side of the Monitored Light Curtain transmitter and receiver INSTALLATION T R DOOR 1 DOOR 2 DOOR 3 R Receiving Monitored Light Curtain T Transmitting Monitored Light Curtain R T T R T R T R Blocking Material R Receiving Monitored Light Curtain T Transmitting Monitored Light Curtain Screw ...

Page 5: ...Set of Monitored Light Curtain section INSTALLATION INSTALL ONE SET OF MONITORED LIGHT CURTAINS ON TOP OF PHOTO SENSOR EYE Monitored Light Curtains may also be used as a 2nd Monitored device in tandem with a photo eye on LOGIC 5 0 and HCT Operators The lowest beam of the Primary monitoring device must be mounted no higher than 6 above the ground The vertical distance between the photo eye and the ...

Page 6: ... CLOSE OPEN TTC 24VAC 24VAC LMEP EDGE OPEN CLOSE MAS COMMON TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Blue Brown Logic Board Logic Board Brown Blue White Black Black White Brown Blue HEAVY AND STANDARD DUTY LOGIC 5 0 manufactured 2014 and later MEDIUM DUTY LOGIC manufactured after 2010 FIRE DOOR MODEL ...

Page 7: ...and reverse TEST THE PHOTOELECTRIC SENSORS IF PRESENT IN THE APPLICATION 1 With the door in the full open position place a solid object in the path of the photoelectric sensors and press the close button The operator should not move 2 Remove the solid object and press the close button The door should close 3 While the door is closing obstruct the photo beam by moving a solid object in the path of ...

Page 8: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Modèles LC36M LC36M41 Rideau de détection lumineux LiftMaster REMARQUE Les images ne sont pas à l échelle ...

Page 9: ...elles et roulantes Il est conçu avec 8 capteurs optiques qui forment 22 faisceaux lumineux invisibles qui forment au total 22 faisceaux lumineux invisibles Ces faisceaux lumineux créent un motif croisé ou un effet de filet pour une protection maximale contre le coincement Lorsqu il est correctement connecté et aligné le rideau de détection lumineux détecte toute obstruction dans la trajectoire des...

Page 10: ...UL et compatible avec LiftMaster LOGIC 5 0 standard moyen et lourd DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL opérateurs de porte coupe feu FDC FDCL FDO A FDO B et opérateurs de porte commerciale d évacuation LGE La rideau de détection lumineux est conçu à un usage intérieur uniquement mais peut être installé dans des zones exposées à la pluie ou à l humidité INTRODUCTION Les images de c...

Page 11: ...eux Si nécessaire inversez le côté de montage de l émetteur et du récepteur du rideau de détection lumineux INSTALLATION R E E R E R PORTE N 1 PORTE N 2 PORTE N 3 E R E R Matériel de blocage Vis Support de fixation Écrou avec guide en nylon R Rideau de lumière surveillé récepteur E Rideau de lumière surveillé émetteur Dans les environnements hautement réfléchissants une séparation allant jusqu à 3...

Page 12: ...UE CAPTEUR DE LUMIÈRE Les rideaux de détection lumineux peuvent également être utilisés comme deuxième dispositif surveillé en tandem avec une cellule photoélectrique capteur de lumière sur les opérateurs LOGIC 5 0 et HCT La poutre la plus basse du dispositif de surveillance principal ne doit pas être montée à plus de 6 po du sol La distance verticale entre la cellule photoélectrique et le bas du ...

Page 13: ...C 24VAC LMEP EDGE OPEN CLOSE MAS COMMON TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Bleu Brun Carte mère Carte mère Brun Bleu Blanc Noir Noir Blanc Brun Bleu LOGIC 5 0 STANDARD ET LOURD fabriqués à partir de 2014 LOGIC MOYEN fabriqués après 2010 PORTE COUPE FEU MODÈLE FDO B LJ8900W LJ8950W DDO8900W VFOH ...

Page 14: ...ESTER LES CAPTEURS PHOTOÉLECTRIQUES LE CAS ÉCHÉANT 1 Lorsque la porte est en position d ouverture complète placez un objet solide dans la trajectoire des capteurs photoélectriques et appuyez sur le bouton de fermeture L opérateur ne doit pas bouger 2 Retirez l objet solide et appuyez sur le bouton de fermeture La porte doit se fermer 3 Pendant que la porte se ferme obstruez le faisceau photoélectr...

Page 15: ...LiftMaster 300 Windsor Drive Oak Brook IL 60523 1510 Modelo LC36M LC36M41 Cortina de luz monitoreada LiftMaster NOTA las imágenes no están a escala ...

Page 16: ...ra el atrapamiento que se utiliza con puertas seccionales y enrollables y está diseñado con 8 sensores ópticos que forman 22 haces de luz invisibles en total Estos haces de luz crean un patrón cruzado o un efecto de red para una máxima protección contra el atrapamiento Cuando se conecta y alinea correctamente la cortina de luz monitoreada detectará una obstrucción que ocurra en el camino de los ha...

Page 17: ...a aprobación UL y es compatible con operadores de puertas LiftMaster de servicio pesado y estándar LOGIC 5 0 de servicio mediano DDO8900W LJ8900W LJ8950W ATSW VFOH HPH1 HPH2 HCTDCUL operadores de puertas contraincendios FDC FDCL FDO A FDO B y operadores de puertas comerciales de evacuación LGE La cortina de luz monitoreada es solo para uso en interiores pero puede instalarse en áreas expuestas a l...

Page 18: ... los sensores ópticos del receptor de la cortina de luz monitoreada Si es necesario cambie el lado de montaje del transmisor y receptor de la cortina de luz monitoreada INSTALACIÓN R T T R T R PUERTA 1 PUERTA 2 PUERTA 3 T R T R Material de bloqueo Tornillo Ménsula de montaje Tuerca con inserto de nylon R Cortina monitoreada de rayos infrarrojos receptora T Cortina monitoreada de rayos infrarrojos ...

Page 19: ...O DE CORTINAS DE LUZ MONITOREADA EN LA PARTE SUPERIOR DEL OJO DEL FOTOSENSOR Las cortinas de luz monitoreada también se pueden usar como un segundo dispositivo monitoreado junto con una fotocélula en los operadores LOGIC 5 0 y HCT El haz de luz más bajo del dispositivo de monitoreo primario debe montarse a no más de 6 sobre el suelo La distancia vertical entre el ojo de la fotocélula y la parte in...

Page 20: ...N TIMER DEFEAT POWER TIMER ENABLE 3 3 PHASE 1 PHASE J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 10 11 12 13 14 Azul Marrón Tarjeta lógica Tarjeta lógica Marrón Azul Blanco Negro Negro Blanco Marrón Azul LOGIC 5 0 DE SERVICIO PESADO Y ESTÁNDAR fabricado en 2014 y posterior LOGIC DE SERVICIO MEDIANO fabricado después de 2010 PUERTA CONTRAINCENDIOS MODELO FDO B LJ8900W L...

Page 21: ...ORES FOTOELÉCTRICOS SI ESTÁN PRESENTES EN LA APLICACIÓN 1 Con la puerta en la posición completamente abierta coloque un objeto sólido en el camino de los sensores fotoeléctricos y presione el botón de cierre El operador no debe moverse 2 Quite el objeto sólido y presione el botón de cierre La puerta debe cerrarse 3 Mientras la puerta se cierra obstruya el haz de fotocélulas moviendo un objeto sóli...

Page 22: ... 2021 LiftMaster All Rights Reserved Tous droits réservés Todos los derechos reservados 114 5541C ...

Reviews: