Chamberlain K001A3200-2 Manual Download Page 2

2

TEST THE UNIVERSAL RECEIVER FOR DAMAGE

You may need to replace the pre-installed universal receiver 
(model 850LM). To test the universal receiver for damage:
1.  Disconnect power to the operator.
2.  Disconnect the universal receiver from the operator.
3.  Configure a digital voltmeter to measure resistance.
4.  Connect the negative or black lead of the voltmeter to the “F” 

connector used to ground the universal receiver antenna.

5.  Connect the positive or red lead of the voltmeter to:
 

a.  The + power input of the universal receiver. If the meter 

reads (0Ω), there is a short indicating the universal receiver 
is damaged. 

Replace the universal receiver

 

b.  The - power input of the universal receiver. If the meter 

reads (0Ω), there is a short indicating the universal receiver 
is damaged. 

Replace the universal receiver

 

NOTE:

 Don’t confuse 0Ω with ∞Ω.

6.  If the voltmeter does not indicate a short, the universal 

receiver can be used.

INSTALL THE ISOLATION KIT

To install the isolation kit:
1.  Disconnect power to the operator.
2.  Remove all accessories from the operator.
3.  Locate the chassis-mounted “F” connector (where the coax 

antenna passes through the operator chassis). Location 
varies depending on the operator, refer to the owner’s 
manual.

4.  Disconnect the coax cables from both sides of the “F” 

connector.

5.  Remove the “F” connector and the mounting hardware. Set 

aside for reinstallation.

6.  Drill out the hole using a 1/2" drill bit.
7.  Reinstall the “F” connector to the chassis. Insert the isolation 

washers between the operator chassis and the other 
hardware. The shoulder washer should go on the inside of the 
operator. The flat washer should go on the outside of the 
operator. See illustration for assembly order.

8.  Reconnect the coax cables to the “F” connector.
9.  Connect the antenna ground to the chassis.
10.  Connect all other accessories according to the instructions 

that came with them.

11.  Restore power and test the operator.

Chassis

Nylon flat washer

“F” connector

To antenna

Nylon
shoulder
washer

(+) power

input

(-) power

input

Summary of Contents for K001A3200-2

Page 1: ...er to measure AC voltage Make 3 voltage measurements between the following points R1 R2 R1 chassis ground and R2 chassis ground Location varies depending on the operator refer to the owner s manual If there is no voltage between R1 R2 check to see if the transformer fuse is blown If the fuse is blown replace with the appropriate fuse included in the kit and measure voltage again 6 Refer to the tab...

Page 2: ...r can be used INSTALL THE ISOLATION KIT To install the isolation kit 1 Disconnect power to the operator 2 Remove all accessories from the operator 3 Locate the chassis mounted F connector where the coax antenna passes through the operator chassis Location varies depending on the operator refer to the owner s manual 4 Disconnect the coax cables from both sides of the F connector 5 Remove the F conn...

Page 3: ...tension entre les points suivants R1 R2 R1 masse du châssis et R2 masse du châssis L emplacement varie en fonction de l actionneur consulter à cet effet le manuel du propriétaire S il n y a aucune tension entre R1 R2 vérifier si le fusible du transformateur est grillé Si le fusible est grillé le remplacer par le fusible approprié inclus dans le nécessaire et mesurer de nouveau la tension 6 Consult...

Page 4: ...é INSTALLER LE NÉCESSAIRE D ISOLATION Pour installer le nécessaire d isolation 1 Déconnecter l alimentation à l actionneur 2 Déposer tous les accessoires de l actionneur 3 Localiser le connecteur F monté sur le châssis où l antenne coaxiale passe par le châssis de l actionneur L emplacement varie en fonction de l actionneur consulter à cet effet le manuel du propriétaire 4 Déconnecter les câbles c...

Page 5: ...ltaje de corriente alterna Tomar tres medidas de voltaje entre los siguientes puntos R1 R2 R1 tierra de chasis y R2 tierra de chasis El lugar de instalación dependerá del tipo de operador Consultar el manual de instrucciones Si no se midiera voltaje entre R1 R2 verificar que el fusible del transformador no estuviera quemado Si el fusible estuviera quemado cambiarlo por el fusible del juego y volve...

Page 6: ...stalar el juego de aislamiento 1 Desconectar la alimentación eléctrica del operador 2 Desconectar todos los accesorios del operador 3 Ubicar el conector F montado en el chasis adonde la antena coaxial pasa por el chasis del operador El lugar de instalación dependerá del tipo de operador Consultar el manual de instrucciones 4 Desconectar los cables coaxiales de ambos lados del conector F 5 Quitar e...

Page 7: ...7 ...

Page 8: ... 2015 LiftMaster All Rights Reserved Tous droits réservés 01 37828B Todos los derechos reservados ...

Reviews: