The Chamberlain Group, Inc.
New Wiring Kit Art
2/19/94
TYPE
STATION
B2
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close and stop, plus wiring for
sensing device to reverse and auxiliary devices to open and close
with open override.
C2
3 Button, 3 Button Radio Control
Function: Momentary contact to open and stop with constant pressure
to close, open override plus wiring for sensing device to reverse.
D1
2 Button, 3 Button Radio Control
Function: Constant pressure to open and close with wiring for sensing
device to stop.
E2
2 Button, 3 Button Radio Control
Function: Momentary contact to open with override and constant
pressure to close. Release of close button will cause door to reverse
(roll-back feature) plus wiring for sensing device to reverse.
T*
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close, and stop, with open
override and timer to close. Every device that causes door to open,
except a reversing device, activates timer to close. Auxiliary controls
can be connected to open input to activate the timer to close. If the
timer has been activated, the open button and radio control can
recycle the timer. The stop button will deactivate the timer until the
close button is used to close the door. (NOTE: Requires P/N 1A4811
CPSII Option Board with Timer to Close Function.)
TS*
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close, and stop with open
override and timer to close. Every device that causes door to open,
including a reversing device, activates timer to close. Auxiliary
controls can be connected to open input to activate the timer to close.
If the timer has been activated, the open button and radio control can
recycle the timer. The stop button will deactivate the timer until the
close button is used to close the door. (NOTE: Requires P/N 1A4811
CPSII Option Board with Timer to Close Function.)
NOTE:
1. External interlocks may be used with all functional modes.
2. Auxiliary devices are any devices that have only one set of
contacts. Examples are: photocell, loop detector, pneumatic or
electrical treadles, residential radio controls, one button stations,
pull cords, etc.
3. Open override means that the door may be reversed while closing
by activating an opening device without the need to use the stop
button first.