Remove 
2 x 4

Close door

Attach Hanging Brackets to Ceiling and Fasten Motor Unit to Hanging Brackets 

Remove 2x4 and Close Door

C9 

Hex Bolt 

C4 

Nut  

C5 

Lock Washer 

C8 

Lag Screw 

ALL HARDWARE SHOWN ACTUAL SIZE

2 x 4

If the top section or panel hits the trolley when you raise 
the door, pull down on the trolley release arm to 
disconnect inner and outer sections. Slide the outer trolley 
t oward the motor unit. The trolley can remain 
disconnected until installation is completed.

NOTE: 

The garage door opener motor head will typically 

sit lower than the header bracket, therefore, the rail will be 
at an angle.

Open Door to Full Open Position and Rest Rail 
on a 2x4 to Position Opener at the Proper 
Angle for Hanging from the Ceiling

POSITION AND HANG MOTOR UNIT

NOTE: 

Before the motor unit is secured to the ceiling, insure that the motor unit and rail are centered 

over the door. If you mounted the header bracket off center, hang the motor unit the same distance.
Concrete anchors must be used if installing any brackets into masonry.

Measure
Distance

C8 

Lag Screws 

C9 

Hex

 

Bolt

C5 

Lock Washer 

C4 

Nut 

Bracket
(Not Provided)

(Not Provided)
Bolt 5/16"-18 x 7/8" 
Lock Washer 5/16" 
Nut 5/16" - 18 

C9 

Hex

 

Bolt

C5 

Lock Washer 

C4 

Nut 

C8 

Lag Screws or 

       Concrete Anchors (Not Provided)

Option with unfinished ceiling

Option with finished or unfinished ceiling

OR

1

2

3

To prevent damage to garage door, rest garage door opener 
rail on 2 x 4 placed on top section of door.

WARNING

CAUTION

CAUTION

WARNING

WARNING

To avoid possible SERIOUS INJURY from a falling garage door 
opener, fasten it securely to structural supports of the garage.

WARNING

WARNING

CAUTION

WARNING

WARNING

Summary of Contents for 248730DM

Page 1: ...hock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your garage door and or the garage door opener if you do not com...

Page 2: ...ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement WARNING WARNING CAUTION WARNING CAUTION CAUTION Sectional Door Preparing Your Garage Door 2 Comp...

Page 3: ...garage door where it meets the floor Any gap between the floor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floo...

Page 4: ...ag e door and o r the garag e door open er if you do not comp ly with the cautio nary state ment s that accom pany it Read them caref ully Mec han ical Elec trica l W WARN ARNING ING CAUTION WA RNING...

Page 5: ...Clevis Pin 5 16 x 1 1 4 1 Self Threading Screw 1 4 14 x 5 8 2 2 Conductor Bell Wire White White Red Screw 6AB x 1 1 4 2 Screw 6 32 x 1 2 Spacer 2 Clevis Pin 5 16 x 1 1 C21 NOTICE Handle not shown actu...

Page 6: ...ert a screwdriver into the hole 10 25 cm away from the front of the rail as shown To prevent INJURY from pinching keep hands and fingers away from the joints while assembling the rail WARNING CAUTION...

Page 7: ...LY use bolts fasteners mounted in top of motor unit WARNING CAUTION CAUTION Cable Loop B4 Master Link Clip On Spring B4 Master Link Bar A2 Chain and Cable Do NOT remove Chain Cable from box B4 Master...

Page 8: ...aded Shaft C4 Inner Nut C5 Lock Washer Attach Nut and Lock Washer to Trolley Threaded Shaft Tighten the Chain Base of Rail Mid Length of Rail A2 Chain 1 4 6 mm Desired Chain Tension B4 Master Link C4...

Page 9: ...e One Piece Door Installation Instructions included with your garage door opener Sectional Door One Piece Door GARAGE DOOR OPENER ASSEMBLY INSTALLATION MANUAL n Ple ase rea d this ma nual and the encl...

Page 10: ...it to the ceiling when clearance is minimal Fasten header bracket securely to structural supports It may be necessary to use a 2 x 4 as a structural support if installing on drywall or between two st...

Page 11: ...ntal line made in Step 2 Highest Point of Travel A14 Bracket Mark the top and bottom bracket holes Horizontal Line Center of Garage Door Drill two 3 16 pilot holes UP Secure bracket with lag screws C1...

Page 12: ...ing from the Ceiling POSITION AND HANG MOTOR UNIT NOTE Before the motor unit is secured to the ceiling insure that the motor unit and rail are centered over the door If you mounted the header bracket...

Page 13: ...s Position the door bracket on the face of the door within the following limits 1 The top edge of the bracket 2 4 5 10 cm below the top edge of the door 2 The top edge of the bracket directly below an...

Page 14: ...Trolley Slide Trolley Back 2 5 cm and Connect Straight Door Arm to the Trolley Connect Curved Door Arm to the Door Bracket Ensure Door is Fully Closed and Connect Door Arms CONNECT DOOR ARM TO TROLLEY...

Page 15: ...RE installing Door Control Connect ONLY to 24 VOLT low voltage circuit To prevent possible SERIOUS INJURY or DEATH from a closing garage door Install Door Control within sight of garage door out of re...

Page 16: ...sure power is NOT connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection Garage door installation and wiring MUST be in compliance with...

Page 17: ...brackets are designed to clip onto the track of sectional garage doors without additional hardware Invisible Light Beam Protection Area Safety Reversing Sensor no higher than 6 15 cm above floor Safet...

Page 18: ...4 Carriage Bolt ALL HARDWARE SHOWN ACTUAL SIZE INSTALL THE PROTECTOR SYSTEM A9 Extension Bracket Inside Garage Wall Provided with Extension Bracket Provided with Extension Bracket OR Wall installation...

Page 19: ...into the white quick connect terminal and insert the two black white wires into the grey quick connect terminal White Wires Black White Wires White Terminal Grey Terminal Screwdriver KG KG Connect Saf...

Page 20: ...adjustment NOTE Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off Simply wait 15 minutes and try again NOTE If anything interferes with the do...

Page 21: ...the DOWN close force Grasp the door bottom when the door is about halfway through DOWN close travel The door should reverse Reversal halfway through down travel does not guarantee reversal on a 1 1 2...

Page 22: ...more than an inch and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misali...

Page 23: ...ecurity Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any of the following The...

Page 24: ...at again for a 3 1 2 minute interval etc up to a maximum of four blinks and 4 1 2 minutes Lock Feature Designed to prevent operation of the door from hand held remote controls However the door will op...

Page 25: ...reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to...

Page 26: ...If motor unit doesn t operate motor unit is overheated Wait 15 minutes and retry If motor unit still will not operate replace logic board Symptom Sending indicator light glows steadily receiving indi...

Page 27: ...Multi Function Door Control LOCK LIGHT LOCK LIGHT 1 Press and hold the button on the hand held remote that you wish to operate your garage door 2 While holding the remote button press and hold the li...

Page 28: ...ss and hold enter 2 While holding the ENTER button press and hold the LIGHT button on the Multi Function Door Control 3 Continue holding the ENTER and LIGHT buttons while you press the push bar on the...

Page 29: ...for your personal entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then...

Page 30: ...mote control 3 953D 3 button remote control 4 10A20 3V2032 Lithium battery 5 29B137 Remote control visor clip 6 41A2828 Emergency release rope and handle assembly 7 41B4494 1 2 conductor bell wire whi...

Page 31: ...10 41A3150 Terminal block with screws 11 41A5525 5 Cover 12 41D3452 Limit switch assembly KEY PART NO NO DESCRIPTION 13 41D3058 Universal replacement motor and bracket assembly Complete with Motor wo...

Page 32: ...tion Door Control Panel Provides a Lock feature which prevents operation of garage door opener from portable remotes and a Light feature for constant light 945CB 7708CB 41A5281 Outside Quick Release R...

Page 33: ...33 NOTES...

Page 34: ...34 NOTES...

Page 35: ...y gives you specific legal rights and you may also have other rights which vary from state to state CHAMBERLAIN 1 YEAR LIMITED WARRANTY LIFETIME MOTOR LIMITED WARRANTY PD610DM PD612DM PD612KLDM 48930D...

Page 36: ...call our Service number for a list of dealers in your area HOW TO ORDER REPAIR PARTS Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed a...