background image

C7 

Clevis Pin 

C21 

Clevis Pin 

C6 

Ring Fastener 

C5 

Lock Washer 

C4 

Nut 

C9 

Hex Bolt 

ALL HARDWARE SHOWN ACTUAL SIZE

Pull Down
to Release 
Trolley

C4 

 

Nut

C5 

 

Lock
Washer

C9 

Hex

 

Bolt

A1 

Curved
Door Arm

A5 

Straight 
Door Arm

14

ENGAGED

Attach Emergency Release Rope and Handle

C21 

Clevis Pin

C5

Ring
Fastener

A5 

Straight 
Door Arm

Connect 
Straight
Door Arm 
to Trolley

2" (5 cm)

Connect Curved 
Door Arm to
Door Bracket

C7 

Clevis Pin

C6 

Ring
Fastener

A1 

Curved
Door Arm

ATTACH DOOR TO TROLLEY

Overhand
Knot

NOTICE

C19

 

Rope

C20

 Emergency 

Release Handle

Secure handle with overhand knot 
and heat seal rope.

Pull Emergency Release Rope to Disengage 
the Trolley

Slide Trolley Back 2" (5 cm) and Connect Straight 
Door Arm to the Trolley

Connect Curved Door Arm to the Door Bracket

Ensure Door is Fully Closed and Connect 
Door Arms

CONNECT DOOR ARM TO TROLLEY

 RELEASED

NOTE: 

Handle should hang 6 feet (1.5 m) above floor. 

Ensure that the rope and handle clear the tops of all 
vehicles to avoid entanglement.

1

2

3

4

5

 To prevent possible SERIOUS INJURY or DEATH from a falling 
garage door:
•  If possible, use emergency release handle to disengage 

trolley ONLY when garage door is CLOSED. Weak or broken 
springs or unbalanced door could result in an open door 
falling rapidly and/or unexpectedly.

•  NEVER use emergency release handle unless garage doorway 

is clear of persons and obstructions.

•  NEVER use handle to pull door open or closed. If rope knot 

becomes untied, you could fall.

WARNING

WARNING

CAUTION

WARNING

WARNING

Summary of Contents for 248730DM

Page 1: ...hock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your garage door and or the garage door opener if you do not com...

Page 2: ...ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement WARNING WARNING CAUTION WARNING CAUTION CAUTION Sectional Door Preparing Your Garage Door 2 Comp...

Page 3: ...garage door where it meets the floor Any gap between the floor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floo...

Page 4: ...ag e door and o r the garag e door open er if you do not comp ly with the cautio nary state ment s that accom pany it Read them caref ully Mec han ical Elec trica l W WARN ARNING ING CAUTION WA RNING...

Page 5: ...Clevis Pin 5 16 x 1 1 4 1 Self Threading Screw 1 4 14 x 5 8 2 2 Conductor Bell Wire White White Red Screw 6AB x 1 1 4 2 Screw 6 32 x 1 2 Spacer 2 Clevis Pin 5 16 x 1 1 C21 NOTICE Handle not shown actu...

Page 6: ...ert a screwdriver into the hole 10 25 cm away from the front of the rail as shown To prevent INJURY from pinching keep hands and fingers away from the joints while assembling the rail WARNING CAUTION...

Page 7: ...LY use bolts fasteners mounted in top of motor unit WARNING CAUTION CAUTION Cable Loop B4 Master Link Clip On Spring B4 Master Link Bar A2 Chain and Cable Do NOT remove Chain Cable from box B4 Master...

Page 8: ...aded Shaft C4 Inner Nut C5 Lock Washer Attach Nut and Lock Washer to Trolley Threaded Shaft Tighten the Chain Base of Rail Mid Length of Rail A2 Chain 1 4 6 mm Desired Chain Tension B4 Master Link C4...

Page 9: ...e One Piece Door Installation Instructions included with your garage door opener Sectional Door One Piece Door GARAGE DOOR OPENER ASSEMBLY INSTALLATION MANUAL n Ple ase rea d this ma nual and the encl...

Page 10: ...it to the ceiling when clearance is minimal Fasten header bracket securely to structural supports It may be necessary to use a 2 x 4 as a structural support if installing on drywall or between two st...

Page 11: ...ntal line made in Step 2 Highest Point of Travel A14 Bracket Mark the top and bottom bracket holes Horizontal Line Center of Garage Door Drill two 3 16 pilot holes UP Secure bracket with lag screws C1...

Page 12: ...ing from the Ceiling POSITION AND HANG MOTOR UNIT NOTE Before the motor unit is secured to the ceiling insure that the motor unit and rail are centered over the door If you mounted the header bracket...

Page 13: ...s Position the door bracket on the face of the door within the following limits 1 The top edge of the bracket 2 4 5 10 cm below the top edge of the door 2 The top edge of the bracket directly below an...

Page 14: ...Trolley Slide Trolley Back 2 5 cm and Connect Straight Door Arm to the Trolley Connect Curved Door Arm to the Door Bracket Ensure Door is Fully Closed and Connect Door Arms CONNECT DOOR ARM TO TROLLEY...

Page 15: ...RE installing Door Control Connect ONLY to 24 VOLT low voltage circuit To prevent possible SERIOUS INJURY or DEATH from a closing garage door Install Door Control within sight of garage door out of re...

Page 16: ...sure power is NOT connected to the opener and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection Garage door installation and wiring MUST be in compliance with...

Page 17: ...brackets are designed to clip onto the track of sectional garage doors without additional hardware Invisible Light Beam Protection Area Safety Reversing Sensor no higher than 6 15 cm above floor Safet...

Page 18: ...4 Carriage Bolt ALL HARDWARE SHOWN ACTUAL SIZE INSTALL THE PROTECTOR SYSTEM A9 Extension Bracket Inside Garage Wall Provided with Extension Bracket Provided with Extension Bracket OR Wall installation...

Page 19: ...into the white quick connect terminal and insert the two black white wires into the grey quick connect terminal White Wires Black White Wires White Terminal Grey Terminal Screwdriver KG KG Connect Saf...

Page 20: ...adjustment NOTE Repeated operation of the opener during adjustment procedures may cause the motor to overheat and shut off Simply wait 15 minutes and try again NOTE If anything interferes with the do...

Page 21: ...the DOWN close force Grasp the door bottom when the door is about halfway through DOWN close travel The door should reverse Reversal halfway through down travel does not guarantee reversal on a 1 1 2...

Page 22: ...more than an inch and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misali...

Page 23: ...ecurity Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any of the following The...

Page 24: ...at again for a 3 1 2 minute interval etc up to a maximum of four blinks and 4 1 2 minutes Lock Feature Designed to prevent operation of the door from hand held remote controls However the door will op...

Page 25: ...reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to...

Page 26: ...If motor unit doesn t operate motor unit is overheated Wait 15 minutes and retry If motor unit still will not operate replace logic board Symptom Sending indicator light glows steadily receiving indi...

Page 27: ...Multi Function Door Control LOCK LIGHT LOCK LIGHT 1 Press and hold the button on the hand held remote that you wish to operate your garage door 2 While holding the remote button press and hold the li...

Page 28: ...ss and hold enter 2 While holding the ENTER button press and hold the LIGHT button on the Multi Function Door Control 3 Continue holding the ENTER and LIGHT buttons while you press the push bar on the...

Page 29: ...for your personal entry PIN not the last temporary PIN then press and hold the button The opener light will blink three times Release the button 2 Press the temporary 4 digit PIN you have chosen then...

Page 30: ...mote control 3 953D 3 button remote control 4 10A20 3V2032 Lithium battery 5 29B137 Remote control visor clip 6 41A2828 Emergency release rope and handle assembly 7 41B4494 1 2 conductor bell wire whi...

Page 31: ...10 41A3150 Terminal block with screws 11 41A5525 5 Cover 12 41D3452 Limit switch assembly KEY PART NO NO DESCRIPTION 13 41D3058 Universal replacement motor and bracket assembly Complete with Motor wo...

Page 32: ...tion Door Control Panel Provides a Lock feature which prevents operation of garage door opener from portable remotes and a Light feature for constant light 945CB 7708CB 41A5281 Outside Quick Release R...

Page 33: ...33 NOTES...

Page 34: ...34 NOTES...

Page 35: ...y gives you specific legal rights and you may also have other rights which vary from state to state CHAMBERLAIN 1 YEAR LIMITED WARRANTY LIFETIME MOTOR LIMITED WARRANTY PD610DM PD612DM PD612KLDM 48930D...

Page 36: ...call our Service number for a list of dealers in your area HOW TO ORDER REPAIR PARTS Selling prices will be furnished on request or parts will be shipped at prevailing prices and you will be billed a...