![Challenger HQ006 Installation And Operation Manual Download Page 7](http://html1.mh-extra.com/html/challenger/hq006/hq006_installation-and-operation-manual_2586201007.webp)
QAD#IM6010 RevD 11.01.19
Internal Parts for Standard Models
Internal Parts - HQ006 Series
1. Motor
2. Indicator
3. Open Limit Switch
4. Additional Open Limit Switch
5. Close Limit Switch
6. Additional Close Limit Switch
7. Potentiometer Unit
8. Terminal
9. Heater
10. Capacitor
INSTALLATION INSTRUCTION
Pre-Installation (for use in General Services)
Verify the actuators name plate to ensure correct model number, force, operating speed, voltage and enclosure type before instal-
lation and use.
It is important to verify that the output force of the actuator is appropriate for the force requirements of the valve and that the
actuator duty cycle is appropriate for the intended application.
WARNING: Read this installation and maintenance manual carefully and completely before attempting to install , operate or
trouble shoot the HKC actuator.
Actuator Mounting
Note:
Prior to mounting the part-turn actuator it must be checked for damage.
Damaged parts must be replaced by original spare parts.
Mounting is most effectively carried out with the valve shafting pointing vertically upwards, however mounting is also possible in
any other position.
The HQ series actuators are supplied with a Union Joint and nut which is removable for ease of machining.
CAUTION:
Do not attempt to work on your HKC actuator without first shutting off Incoming power.
Do not attach ropes or hooks to the hand wheel for the purpose of lifting by hoist.
7