10-5
SECTION 10
SLIDEOUT / LEVELING
Class A
If an error is detected, the green LED on the
left side of the control panel will blink an error
code. If an error code appears, see the Error
Codes chart in your InfoCase. The error code
must be cleared prior to operating the room. To
clear the error, press the “RESET” button with a
small tool such as a toothpick. Before operating
the room after an error has been detected, check
for obvious faults such as obstructions before
trying to operate the room again. If the error code
appears again, the room will need to be extended
using the crank method described in the previous
section. The crank method is provided as a means
to extend the room if there is a failure in the
automatic system. If the room must be extended
using the crank method, keep in mind it is likely
that it must also be cranked in to retract. After the
outing is completed and the room is retracted
fully, take the coach to the nearest authorized
service center for inspection.
Further Information
See the DigiSync Slideout Room operating
guide included in your InfoCase for further
instructions, and troubleshooting information.
BEDROOM SLIDEOUT
Emergency Retraction Procedure
Models 26PR, 29RR, 34AR & 35NR
1. Locate the tools in the right front side storage
compartment - a ratchet wrench, a hex-end
shaft and an extension shaft. (The ratchet
wrench may be packaged in the InfoCase.)
2. Locate the small, round access hole in the bed
base at the foot of the bed.
3. Attach the shaft extension to hex-end shaft
and place the ratchet wrench onto the hex end
shaft, then insert into the hole in the bed base
as shown.
Green light will flash error code,
if system malfunctions
Diagnostics
Reset Button
Red light will flash if park
brake not set.