CHAFFOTEAUX PIGMA EVO 25 CF Installation And Servicing Instructions Download Page 8

8

Περιγραφή προϊόντος

Product description

PIGMA/PIGMA SYSTEM

ΠΙΝΑΚΑΣ ΧΕΙΡΙΣΤΗΡΙΩΝ

OVERALL VIEW

Legend 

1.  Flue 

connector

2. Fume 

sensor

3. Combustion 

Hood

4. 

Main Heat Exchanger

6. 

C.H. Flow temperature probe

7. Burner
8. Ignition 

electrodes

9. Gas 

valve

10. Spark 

generator

12.  Safety valve (3 bar)
13.  Secondary heat exchanger
15. Filling 

valve

16.  C.H. circuit fi lter
17.  D.H.W. Flow switch
18.  Circulation Pump with air release valve
19. Diverter 

valve

20.  C.H. Return temperature probe
21. Detection 

Electrode

22. Combustion 

Chamber

23. Expansion 

vessel

1

2

3

4

6

7
8

9

10

12

13

23

22

21

19

20

18

17
16

15

15

1

2

3

4

6

7
8

9

10

12

23

22

21

19

20

18

16

PIGMA

PIGMA SYSTEM

Λεζάντα:

1.   Συλλέκτης απαγωγής καυσαερίων
2.   ΑΙΣΘΗΤΗΡΑΣ καπνών
3.   Απορροφητήρας καπνών
4.   Πρωτεύων εναλλάκτης
6.   Αισθητήρας κατάθλιψης θέρμανσης
7.   Καυτήρας
8.   Ηλεκτρόδια ανάφλεξης
9.   Βαλβίδα αερίου
10.  Αναφλεκτήρας
12.  Βαλβίδα ασφαλείας 3 bar
13.  Δευτερεύων εναλλάκτης
15.  Κρουνός πλήρωσης
16.  Φίλτρο κυκλώματος θέρμανσης
17.  Ροόμετρο ζεστού νερού
18.  Ρυθμιζόμενος κυκλοφορητής με εξαεριστήρα
19.  Μηχανοκίνητη βαλβίδα εκτροπής
20.  Αισθητήρας επιστροφής θέρμανσης
21.  Ηλεκτρόδιο ανίχνευσης φλόγας
22.  Θάλαμος καύσης
23.  Δοχείο διαστολής

Summary of Contents for PIGMA EVO 25 CF

Page 1: ...PIGMA PIGMA SYSTEM WALL HUNG GAS BOILER GR Installation and Servicing Instructions 25 CF 30 CF mode sra esc menu ok comfort on off reset R V00...

Page 2: ...ocedure 17 First ignition 18 Deaeration cycle 18 Settings 19 Checking the gas settings 19 Maximun Heating Power adjustment 20 Checking slow ignition power 20 Heating ignition delay adjustment 20 Check...

Page 3: ...sure any rolling ladders are positioned securely that they are suitably strong that the steps are intact and not slippery and that the ladders are fitted with handrails on either side of the ladder an...

Page 4: ...itching the external bipolar switch to the OFF position and shut off the gas valve Once work is completed ask a qualified technician to check the efficiency of the ducting and devices Whenever the ext...

Page 5: ...ing So that the normal operation of the boiler is not compromised the place in which it is installed must be suitable with regard to the operating limit temperature value and the appliance should be p...

Page 6: ...sont conformes aux normes en vigueur Si des poussi res et ou vapeurs nocives se trouvent dans le local o la chaudi re est install e celle ci devra fonctionner l aide d un autre circuit d air Cleaning...

Page 7: ...cal system The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply Make sure that the system is abl...

Page 8: ...valve 3 bar 13 Secondary heat exchanger 15 Filling valve 16 C H circuit filter 17 D H W Flow switch 18 Circulation Pump with air release valve 19 Diverter valve 20 C H Return temperature probe 21 Dete...

Page 9: ...A Central Heating Flow B Domestic Hot Water Outlet PIGMA C Gas Inlet D Domestic Cold Water Inlet E Central Heating Return R Tank return PIGMA SYSTEM A B PIGMA C D E R PIGMA SYSTEM PIGMA PIGMA SYSTEM W...

Page 10: ...REEN SYSTEM 12 15 18 25kW FR BE 246 232 388 TALIA SYSTEM TALIA GREEN SYSTEM 12 15 18 25kW 180 166 322 TALIA SYSTEM 30 35kW 180 166 322 TALIA SYSTEM GREEN 30 35kW FR BE 246 232 458 TALIA SYSTEM GREEN 3...

Page 11: ...UX Hydraulic Bar Kit Pour monter la Barrette hydraulique vous devez utiliser le gabarit en papier et tuyaux de raccordement eau gaz inclus dans le kit Une fois la barrette fix e au mur vous avez la po...

Page 12: ...that might compromise satisfactory functioning Solvents or aromatic hydrocarbons petrol kerosene etc must not be used Check that the expansion tank has a capacity adequate for the system s water cont...

Page 13: ...possessions for which the manufacturer shall not be held responsible B 37 Boiler installation fix the boiler support bracket to the wall and align it hang the boiler onto the bracket remove the front...

Page 14: ...door sensor TNK TANK temperature probe PIGMA SYSTEM SOL Solar temperature probe TA1 Room thermostat 1 Room thermostat connection Introduce the thermostat wire Loosen the cable clamp using a screwdrive...

Page 15: ...CN3 1 1 CN8 1 CN25 1 Bk Bl Br CN9 Bk Bk Bk Bk 3 1 2 4 Fume sensor Wh Wh Br Bk Bl LV Connections D H W flow switch PIGMA C H Flow temp probe C H Return temp probe Gas valve HV Connections Diverter valv...

Page 16: ...st 1 bar registers on the pressure gauge Gas supply Proceed in the following manner make sure that the main gas supply uses the same type of gas as indicated on the boiler data plate Open all doors an...

Page 17: ...eration active Hot Water Comfort activated Hot Water Comfort activated with Timer programming Antifreeze function activated SRA SRA function activated temperature control activated Clip in solar conne...

Page 18: ...the system pressure shown on the display unit is higher than 1 2 bar At the end check that the system is completely deaerated and if not repeat the procedure 4 Bleed the air from the radiators 5 The e...

Page 19: ...pressure gauge connection pipe into the pipe tap 2 Disconnect the air chamber compensation tube 3 Switch the boiler on at maximum power enabling the flue sweep function Press the RESET button for 10 s...

Page 20: ...um power allowed by the boiler and the minimum power The display shows the value between 0 and 100 of this interval To check the maximum heating power access menu 2 sub menu 3 parameter 1 check the va...

Page 21: ...nutes or when the RESET button is pressed The table indicate the existing relationship between the gas pressure at the burner and the boiler power level in heating mode Gas Changeover The boiler may b...

Page 22: ...4 27 5 35 3 230 maximum heating absolute parameter 230 11 37 62 26 5 84 34 0 91 11 2 62 27 2 85 35 0 97 minimum 2 2 5 5 6 9 2 5 5 3 7 5 220 Soft light param 220 2 2 0 5 5 0 6 9 0 2 5 0 5 3 0 7 5 0 231...

Page 23: ...s open the cover and proceed as follows for example 231 231 Caution The menus reserved for qualified technicians may only be accessed after setting the access code 1 Press the MENU OK button for 5 sec...

Page 24: ...point Zone2 5 2 Zone 2 Setting 5 3 Diagnostics 6 Zone 3 Parameters 6 0 Set point Zone3 6 2 Zone 3 Setting 6 3 Diagnostics 8 Service Parameter 8 1 Statistics 8 2 Boiler 8 3 Boiler Temperature 8 4 Solar...

Page 25: ...HW Setpoint Temperature PIGMA SYSTEM from 40 to 60 C Setting by DHW Knob 8 2 2 BOILER GENERAL SETTINGS 2 2 0 Soft ignition from 0 to 100 60 see parag Gas settings 2 2 4 Termoregulation 0 Absent 1 Pres...

Page 26: ...n This parameter can be used to set the difference between the flow and return temperatures which determines the commutation between low and high circulation pump speed E g param 14 20 if the Tflow Tr...

Page 27: ...unction can be activated or deactivated by the user as well consult the User s Manual 2 5 1 Comfort Anti cycling Time from 0 to 120 minutes 0 2 5 2 Hot water flow delay from 5 to 200 0 5 to 20 seconds...

Page 28: ...DHW power TEST Minimum power Enabled also by pressing for 10 seconds the Reset button This function is deactivated automatically after 10 minutes or when the RESET button is pressed 2 7 1 Air purge F...

Page 29: ...can be shifted in a parallel manner as indicated in the figure shown below The value is indicated on the display from 14 to 14 C high temperature Each step represents a flow temperature increase decr...

Page 30: ...ture By accessing this parameter or turning the knob 4 the curve can be shifted in a parallel manner as indicated in the figure shown below The value is indicated on the display from 14 to 14 C high t...

Page 31: ...room temperature By accessing this parameter or turning the knob 4 the curve can be shifted in a parallel manner as indicated in the figure shown below The value is indicated on the display from 14 t...

Page 32: ...CE 8 5 0 Months to next maintenance from 0 to 60 month 24 If setted the boiler will display that is time to call the installer for maintenance 8 5 1 Enable Maintenance advice 0 OFF 1 ON 0 8 5 2 Mainte...

Page 33: ...MENU OK button DAY press the MENU OK button and turning the knob 4 to select the day MONTH press the MENU OK button and turning the knob 4 to select the month YEAR press the MENU OK button and turnin...

Page 34: ...ATURE WITH ON OFF ROOM THERMOSTAT OUTDOOR SENSOR In this case the following parameters must be set 4 21 Activation of temperature adjustment using sensors Select 01 outdoor sensor only 4 22 Temperatur...

Page 35: ...he heating circuit is insufficient the boiler will perform a safety shut off On the display flash Err and the code Err 103 for Insufficient circulation see the error table Check the water pressure on...

Page 36: ...en or short circuit ZONA 2 4 13 Room sensor circuit open or short circuit ZONA 3 Ignition and Detecion 5 01 No flame detected 5 02 Flame detected with gas valve closed 5 P1 1st Ignition Failed 5 P2 2n...

Page 37: ...ne 1 send sensor defective 7 02 Zone 2 send sensor defective 7 03 Zone 3 send sensor defective 7 11 Zone 1 return sensor defective 7 12 Zone 2 return sensor defective 7 13 Zone 3 return sensor defecti...

Page 38: ...ternal bipolar switch and shut off the gas valve To access the inside of the boiler the following is necessary 1 Remove the casing by unhooking it from the control panel a 2 Loosen the two screws on t...

Page 39: ...sassemble and clean the combustion chamber if necessary 6 Following the inspection detailed in point 4 disassemble and clean the burner and injector if necessary 7 Cleaning the primary heat exchanger...

Page 40: ...water from the lowest points of the system where applicable WARNING Before handling empty all components which may contain hot water performing bleeding where necessary Descale the components in accor...

Page 41: ...data 10 Maximum domestic hot water pressure 11 Maximum heating pressure 12 Boiler type 13 NOx class Efficiency 14 Input rating nominal heating 15 Power ouput heating 16 DHW specific flow rate 17 Boile...

Page 42: ...47 C 91 2 82 1 89 7 80 8 91 2 82 1 Hi 90 2 81 2 86 5 77 9 90 2 81 2 92 42 Sedbuk D D D 50 C 1 1 1 7 1 1 7 0 7 7 7 0 Pa 3 3 3 NOx 3 3 3 G20 C 118 133 118 CO2 G20 5 8 6 2 5 8 CO 0 O2 ppm 53 41 53 O2 G2...

Page 43: ...0 7 7 7 0 EMISSIONS Residual discharge head Pa 3 3 3 Nox class class 3 3 3 Flue fumes temperature G20 C 118 133 118 CO2 content2 G20 5 8 6 2 5 8 CO content 0 02 ppm 53 41 53 O2 content2 G20 10 1 9 3 1...

Page 44: ...Ariston Thermo SpA Viale A Merloni 45 60044 Fabriano AN Tel 0732 6011 Fax 0732 602331 www chafoteaux gr 420010455200...

Reviews: