7 TEST & UTILITIES
7 0 0 Function test - Cleaning
turn the encoder to select the operating
mode
t-- = funct. at Max heating
power
t-- = funct. at Max DHW power
t-- = funct. at Min power
t--
activation can also be obtained by pressing the Reset
button for 10 seconds. The function is deactivated after
10 minutes or by pressing Reset
7 0 1 Bleed cycle
press Menu
8 PARAMETER FOR TECHNICAL ASSISTANCE
8 1 Entering access code
222 turn the encoder clockwise to select 234 and press the
MENU/OK button
8 BOILER
8 0
NOT PRESENT
8 1 Fan status
ON or OFF
8 Fan speed (x100) rpm
8 Circulation pump speed
OFF - LS - HS
8 4 Distribution valve position
Domestic hot water - Heating
8 5 Water flow rate (l/min)
8 6
NOT PRESENT
8 BOILER TEMPERATURE
8 0 Heating adjustment temperature (°C)
8 1 Heating flow temperature (in °C)
8 Heating backflow temperature (in °C)
8 Domestic hot water temperature (in °C)
8 4 SOLAR APPLIANCE AND TANK
8 4 0 Accumulated measured temperature
activated only with the solar kit connected or external
tank
8 4 1 Solar collector temperature
8 4 Solar appliance water input temperature
8 4 Solar appliance low tank sensor temperature
8 4 5 Total circulation pump operating time delay for solar appliance
8 4 6 Total solar collector overheating time delay
8 5 SERVICE - TECHNICAL ASSISTANCE
8 5 0
Time remaining before next service
setting
from0 to 60 (months)
24 once the parameter is set, the boiler will show the user
the interval before the next service
8 5 1
Service warning authorisation
0 = OFF
1 = ON
OFF once the service has been performed, set the parameter
to clear the warning
8 5
Clearing the service warning
Reset?
OK = yes
ESC = no
8 5
NOT PRESENT
8 5 4 PCB hardware version
8 5 5 PCB software version
8 5 6 PUS peripheral device interface software version