Heat pump water heater - TECHNICAL INFORMATION FOR INSTALLERS
91
Load prifile (
B
)
L
XL
XL
Indoor sound power level (
C
)
dB(A)
53
53
53
EN 16147 (
F
)
COP (
F
)
2,85
3,15
3,06
Heating time (
F
)
h:min
5:21
6:49
6:44
Heating energy consumption (
F
)
kWh
2,584
3,308
3,254
Max. amount of hot water in a single intake V
max
(
F
)
Delivered at 52°C
l
249
321
311
Pes (
F
)
W
27
31
32
Tapping (
F
)
L
XL
XL
812/2013 – 814/2013 (
G
)
Q
elec
(
G
)
kWh
4,092
6,059
6,226
Ƞ
wh
(
G
)
%
118,3
129,6
126,1
Mixed water at 40°C V40 (
G
)
l
249
321
311
Temperature setting (
G
)
°C
52
52
52
Annual electricity consuption (average climatic
condition) (
G
)
kWh/year
866
1293
1328
Load profile (
G
)
L
XL
XL
Heating element
Heating element power
W
2000
Max. water temperature with heating element
ºC
75 (65 factory default setting)
Max. current consumption
A
8,7
Power supply
Voltage / max. power consumption
V / W
220-230 single-phase / 2750
Frequency
Hz
50
Protection rating
IPX4
Air side
Standard air flow rate (automatic modulating control)
m
3
/h
400
Available static pressure
Pa
55
Minimum volume of room of installation (
D
)
m
3
20
Minimum ceiling height of room of installation (
D
)
m
2,06
2,28
2,28
Min. temperature of room of installation
ºC
1
Max. temperature of room of installation
ºC
42
Minimum air temperature (w.b. at 90% r.h.) (
E
)
ºC
-5
Maximum air temperature (w.b. at 90% r.h.) (
E
)
ºC
42
(A)
Values obtained with external air temperature of 7°C and relative humidity at 87%, inlet water temperature of 10°C and set
temperature of 52°C (according to the provisions set forth in EN 16147). Rigid Ø200 ducted product.
(B)
Values obtained with external air temperature of 7°C and relative humidity at 87%, inlet water temperature of 10°C and set
temperature of 52°C (according to the provisions set forth in 2014/C 207/03 - transitional methods of measurement and
calculation). Rigid Ø200 ducted product.