Heat pump water heater - TECHNICAL INFORMATION FOR INSTALLERS
90
2.5 Technical data table
Description
Unit of
measurement
200
240
240 SYS
Rated tank capacity
l
202
244
239
Insulation thickness
mm
≈ 35
Type of internal tank protection
enamelling
Type of corrosion protection
titanium impressed current anode + disposable
magnesium anode
Maximum operating pressure
MPa
0,6
Diameter of hydraulic connections
II
G 3/4 M
Diameter of condensate drainage connection
mm
14
Diameter of air exhaust/intake pipes
mm
150-160-200
Minimum water hardness
°F
12
Minimum conductivity of the water
μS/cm
150
Weight when empty
kg
87
92
107
Heating circuit exchange surface
m
2
-
-
0,65
Max water temperature with external integration
°C
-
-
75
Heat pump
Average electrical power consumption
W
500
Max. electrical power consumption
W
750
Quantity of R134a refrigerant fluid
kg
0,9
Quantity of fluorinated greenhauses gases
Tonnes
CO
2
eq
1,287
Global warning potential
GWP
1430
Max. pressure of refrigerating circuit (low-pressure
side)
MPa
1
Max. pressure of refrigerating circuit (high-pressure
side)
MPa
2,7
Max. water temperature with heat pump
ºC
55
EN 16147 (
A
)
COP (
A
)
2,71
2,86
2,77
Heating time (
A
)
h:min
6:19
7:59
7:57
Heating energy consumption (
A
)
kWh
2,906
3,700
3,646
Max. amount of hot water in a single intake V
max
(
A
)
Delivered at 52°C
l
247
323
313
Pes (
A
)
W
28
34
35
Tapping (
A
)
L
XL
XL
812/2013 – 814/2013 (
B
)
Q
elec
(
B
)
kWh
4,308
6,676
6,887
Ƞ
wh
(
B
)
%
112,3
117,6
114,0
Mixed water at 40°C V40 (
B
)
l
247
323
313
Temperature setting (
B
)
°C
52
52
52
Annual electricity consuption (average climatic
condition) (
B
)
kWh/year
912
1425
1470