BAYARD 10 CFPV & 13 CFPV
OPERATION
When the gas control knob is in the OFF position
( • ) there will be no gas flow into the gas section
of the unit.
By rotating the knob anti - clockwise through the
ignition position ( �
·
) the integral piezo will
operate and generate a spark between the
electrode and the pilot head. Simultaneously the
pilot valve and the thermo - electric valve will be
pushed open, allowing gas to flow into the gas
section chamber and to the pilot head. (The pilot
should light; if not, repeat the operation)
(Fig.1).
After the pilot is lit (knob in PILOT position
*
the knob can be released and the pilot will stay
alight. Allow 15 seconds for the thermo - electric
valve to energise before rotating the knob.
By rotating the control knob further anti
clockwise, the gas control side valve will gradually
open; and on reaching the MAXIMUM position (�)
(Fig.2)
be fully open. By rotating this knob
between maximum and minimum ( �-' ) the
gas rate to the burner can be varied.
By turning on a hot water tap, the main gas valve
(water diaphragm operated) will open and allow
gas to the main burner.
The water flow through the unit can be controlled
by the water control knob situated beneath the
gas control knob (Fig.3).
NOTE:
Should the gas control knob be left in the PILOT
position and the pilot extinguished, pilot gas will
continue to flow from the pilot head. The knob
should not be left in the pilot position. For
extended OFF periods the knob should be
returned to the OFF position.
Fig.
1
Fig. 2
Fig. 3
MAINTENANCE
ENSURE THE APPLIANCE IS ELECTRICALLY SAFE AT ALL TIMES
FRONT CASE REMOVAL
1. Pull off the control knobs.
2. Unscrew the case retention ring from the
water flow control.
Page2
3. Pull the case outward at the bottom to
release the snap catches.
4. Lift the case upwards off the retention tabs
and remove case.