Summary of Contents for VFSL800-N

Page 1: ...ating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference Natural Gas VFSL800 N These appliances conform to the requirements of SAN...

Page 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Page 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Page 4: ...s the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered Natural Gas installer and must comply with the installation...

Page 5: ...in bedrooms or bathrooms where the humidity levels are too high See page 1 Avoid areas where there are strong draughts which may be generated by outside doors It is recommend that the fireplace should...

Page 6: ...nit Connect up according to SANS 10087 1 Connect a copper pipe from the gas supply via a regulator complying with SANS 1237 to the 8 compression fitting on the control valve taking into account the di...

Page 7: ...s before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the required HIGH or LOW setting...

Page 8: ...re glass pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation in the box housing...

Page 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Page 10: ...of malfunction and at least once in 2 years Spiders are the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a...

Page 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...