background image

6

Install outdoor unit

Air purging and leakage test

Electric Wiring

1. Disassemble handle of right side plate or front side plate of outdoor unit.

3.  Ensure if wire has been fixed well.

4.  Install handle or front side plate.

NOTE:

Wrong wiring may cause spare parts malfunction.

After the cable fixed, make sure there should be a free space between the connection and

fixing place on the lead wire.

2. Take off wire clamp, connect and fix power connect cord

 

and power cord to terminal of line 

bank.Wiring should fit that of indoor  unit.

● 

5

 -1.0  10 pa

(-76cmHg).

5

Air purging and leakage test

Liquid pipe

Gas pipe

Valve

cap

Vacuum

gauge

Vacuum pump

Fig.

1. Connect charging hose of manifold valve to charge end of low

pressure valve (both high/low pressure valves must be tightly

shut).

2. Connect joint of charging hose to vacuum pump.
3. Fully open handle of Lo manifold valve.

4. Open the vacuum pump to evacuate. At the beginning, slightly 

loosen joint nut of low pressure valve to check if there 

is air coming inside. (If noise of vacuum pump has 
been changed, the reading of multimeter is 0) Then 
tighten the nut.

5. Keep evacuating for more than 15mins and make 

sure the reading of multi-meter is

6. Fully open high/low pressure valves.

7. Remove charging hose from charging end of low 

pressure valve.

8. Tighten bonnet of low-pressure valve. (As shown in Fig.5)

POWER SUPPLY

Indoor unit connection

2

3

L1

L1

L2

L2

N(1)

2

3

N(1)

G

Outdoor unit connection

Summary of Contents for GWH30LB-D3DNA5E

Page 1: ...VICTORIA HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM INSTALLATION MANUAL Models GWH30LB D3DNA5E 230V GWH36LB D3DNA5E 230V...

Page 2: ...GWH30LB D3DNA5E 230V System Includes GWH30LB D3DNA5E I GWH30LB D3DNA3E O GWH36LB D3DNA5E 230V System Includes GWH36LB D3DNA5E I GWH36LB D3DNA3E O...

Page 3: ...that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related infor...

Page 4: ...ct as the standard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been g...

Page 5: ...the installed location should be 8ft 230cm or more from the floor 6 Select a place about 3 28ft 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be eas...

Page 6: ...ly power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 59in 1...

Page 7: ...6in 15cm 9 8ft 3m 2 6in 15cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e 7 f t 2 m 12in 30cm Above 8 2ft 2 5m Installation dimension diagram Th...

Page 8: ...the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation ma...

Page 9: ...outing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape an...

Page 10: ...cuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum p...

Page 11: ...on Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Outd...

Page 12: ...earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient coolin...

Page 13: ...er it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Ins...

Page 14: ...tion along with the installation data and dealer contact information will be helpful should your system require maintenance or service www cooperandhunter us PRODUCT INSTALLATION RECORD UNIT INFORMATI...

Page 15: ...66160000086 Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 MANUFACTURER GREE ELECTRIC APPLIANCES INC OF ZHUHAI www cooperandhunter us...

Reviews: