Safety Information

1

1 Safety Information

Please read this manual carefully before use this unit, and operate it correctly according to the 

guide in this manual.

Please take specially note to the meaning of these two marks:

Warning!:

 This mark means that it may cause casualty or badly heart if the operation is 

incorrect.

Note!: 

This mark means that it may cause casualty or property loss if the operation is 

incorrect.

Warning:

Do not adopt fuse with unsuitable capacity or adopt iron thread instead of fuse, otherwise 

malfunction or fire may happened.

Cut down the main power switch immediately if malfunction (such as smell the burning odor 

etc.) happened.

Maintain ventilation to prevent oxygen leakage in room.

Don’t insert finger or stick like things into discharge vent or outlet grill.

Please make sure that the unit is installed in the place that can bear the weight of it 

adequately. If the place is not strong enough, the air conditioner may drop and cause casualty event.

Don’t spray or smear any oil paint or insecticide on the surface of unit, otherwise, fire may be 

leaded.

(1). 

Do not refit the conditioner. Please contact the agency or prefect ional personnel to repair or 

move the conditioner.

An all-pole disconnection switch having a contact separation of at least 

1/8” (

3mm

)

 in all 

poles 

should be connected in fixed wiring.

 Note!:

Please check and make sure that the cord, drainage pipe and tubes are connected in the 

correct way to prevent leakage of water, refrigerant, electric shock or fire.

The main power must connectable to the earth in order to assure the conditioner earthing 

effectively and to prevent electric shock. Please don’t connect the earthing line with the gas pipe, 
water pipe, lightening rod or the connecting line of telephone.

The air conditioner should be turned off at least after 5 mins’ operation; otherwise it would 

affect the duration of the unit.

Don’t let the children operate the air conditioner.

Please don’t operate the unit by wet hand.

Please turn off the main power of the unit before cleaning the conditioner or change the filter.

Please cut off the main power if the conditioner will be used for a long time.

Summary of Contents for GKH(12)BA-D3DNA2A/I

Page 1: ...MULTI DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL PANEL CASSETTE TYPE INDOOR UNIT Models GKH 12 BA D3DNA2A I GKH 18 BA D3DNA2A I...

Page 2: ...rating mode of the indoor unit are clash with the operating mode of the outdoor unit the malfunction light will blink after 5s on the indoor unit or remote controller showing that the operation clash...

Page 3: ...the refrigerant pipe 4 2 7 Drainage hose 5 2 8 Electrical wiring 7 2 9 Install the panel 8 3 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 10 4 Working Temperature Range 1...

Page 4: ...ent Don t spray or smear any oil paint or insecticide on the surface of unit otherwise fire may be leaded 1 Do not refit the conditioner Please contact the agency or prefect ional personnel to repair...

Page 5: ...Select the place where easy drain condensated coagulated water and easy connect with outdoor unit 6 Make sure that there are enough space for care and maintenance Make sure that the weight between the...

Page 6: ...3DNA2A I GKH 18 BA D3DNA2A I The drilling of holes in the ceiling must be done by the professional personnel Ceiling Installation stands for main body of the unit 6in 160 mm Above 0 78in 20mm Fig 3 No...

Page 7: ...break off and tighten the nut on it 6 Backout the install cardboard Fig 4 Note Please do tighten the nuts and bolts to prevent air conditioner break off 2 6 Connection of the refrigerant pipe When co...

Page 8: ...iameter of the drain hose should be equal or bigger than the connection pipes The diameter of polythene pipe Outer diameter 1 25mm Surface thickness 1 16 1 5mm Drain hose should be short and drooping...

Page 9: ...tion The slant gradient of the attached drain hose should be within 3in 75mm so that the drain hole doesn t has to endure the unnecessary outside force Fig 9 Please install the drain hose according to...

Page 10: ...ividually by impact fastener Wiring according to the indoor side circuit diagram Fix the impact fastener after connection Entwine the small sponge on the electric wire do entwine it to prevent condens...

Page 11: ...p on the panel of the indoor unit 2 positions Hang the remaining 2 latches to the hooks on the sides of the indoor unit Be careful not to let the swing motor lead wire get caught in the sealing materi...

Page 12: ...height of the indoor unit As shown in fig 15 If the raising lever and drain hose are not affect can adjust the height of indoor unit by the hole on the corner of panel Gaps are not allowed Fig 15 Afte...

Page 13: ...Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 10 3 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit GKH 12 BA D3DNA2A I GKH 18 BA D3DNA2A I...

Page 14: ...e Outdoor side stae Dry bulb temp F C Wet bulb temp F C Dry bulb temp F C Wet bulb temp F C Rated Cooling 81 27 66 19 95 35 75 24 Max cooling 90 32 73 23 118 48 79 26 Min cooling 70 21 59 15 64 18 Rat...

Page 15: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 MANUFACTURER GREE ELECTRIC APPLIANCES INC OF ZHUHAI www cooperandhunter us...

Reviews: