Never expose eyes or skin to UVC light from any source. Looking directly at the UVC

light may cause permanent eye damage or blindness. Never operate the CX-Pro Air Purifying System out
of the plenum. Avoid touching the glass portion of the lamp with your hands.

WARNING

CX-PRO WHOLE HOUSE AIR PURIFIER

MODEL:  CX-Pro

The delivery set includes: 

CX-Pro Air Purifier

120V quick connect power cord

UVC germicidal lamp

#8 sheet metal mounting screws (4)

Ductboard adapter plate

This product is not sold as a medical device and is not for the purpose of

diagnosis of any disease or condition nor for use in the mitigation, treatment, or prevention
of any disease or condition.

BEFORE INSTALLATION

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING

WITH THE INSTALLATION.

Disconnect and lock out power supply before performing any installation work.

Working on or near energized equipment could result in death or serious injury. 

Do not exceed voltage rating. Severe damage to device and/or fire could result.

Verify proper voltage.

This device MUST be installed by a qualified agency in accordance with the manufacturer's installation
instructions. The definition of a qualified agency is any individual, firm, corporation or company that
either in person or through a representative is engaged in, and is responsible for, the installation and
operation of HVAC appliances, who is experienced in such work, familiar with all the precautions
required, and has complied with all the requirements of the authority having jurisdiction.

NOTICE

SPECIFICATIONS

UVC Germicidal Lamp

50 watts 

Length in Duct

17-3/4 in.

Weight

5.5 lbs

Adjustable Voltage

120 or 230 V

Lamp Life Efficiency 

2 years

Average Static Pressure Drop

0.02 in. wg 

Sizing (tons)

1.5 - 5.0 tons

WARNING

NOTICE

WARNING

Summary of Contents for CX-PRO

Page 1: ...Installation Maintenance CX PRO WHOLE HOUSE AIR PURIFIER READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...t install this unit if any damage is noticeable If lamp is damaged cracked or broken do not touch lamp or other contents in carton Close carton and return to seller immediately In case of accidental e...

Page 3: ...Disconnect and lock out power supply before performing any installation work Working on or near energized equipment could result in death or serious injury Do not exceed voltage rating Severe damage t...

Page 4: ...direct exposure of plastic materials or air filters Use care to avoid damage to the AC coil wiring or other components while installing the CX Pro STEP 2 UVC LAMP BALLAST Unplug the unit before insta...

Page 5: ...ully back against the inside of the opening in the ductboard either from the sides or from top and bottom of the plate Finish the ductboard installation by sealing around the edges of the plate to the...

Page 6: ...ase of accidental breakage of glass 1 The lamp should be inspected and cleaned at least every 6 months Frequency depends upon the environment such as the type of air filter duration of use and replace...

Page 7: ...rmal compensating electronic ballast NOTE Wear oil free cotton gloves prior to procedure in case of accidental breakage of glass 1 Follow steps 1 4 in the Lamp Cleaning Procedure above After step 4 lo...

Page 8: ...are not covered by these warranty provisions All warranty claims must be processed through point of purchase All warranty repair work must be performed either at the factory or by a factory certified...

Reviews: