6.
Performance
The pump running under *normal conditions will give you these performances:
*
Normal conditions: geostatic height of 4’ 10” (1.5m), temperature de 59°F (15°C), water clear of sand and
debris, atmospheric pressure < 3280’ (1000m) from sea level
None conformance to the instructions given in this handbook can reduce the
performances given by the pump.
0
1
2
3
4
5
6
7
8
9
10
0
50
100
150
200
250
300
0
10
20
30
40
50
60
70
80
0
25
50
75
100
125
150
Pressure (BAR)
F
lo
w
(
L
P
M
)
F
lo
w
(
G
P
M
)
Pressure (PSI)
Flow (GPM / LPM)
Pressure (PSI / Bar)
70 / 265
10 / 0.7
60 / 227
50 / 3.4
55 / 208
100 / 6.9
40 / 151
125 / 8.6